OPERATION
LED lights
Red LED -ON- when lit, it indicates that the station is
plugged in the mains.
Green LED -READY- when lit, it indicates that the
system is ready and correctly set for working.
The green led light is on after a few seconds, is the
time needed to carry on the self-checking system.
The green light is pulsing when the hot tweezers are
in sleep mode.
If the green led is not lit, the reason why, will be one
of the following:
1. The hot tweezers or the cartridge are not
plugged in.
2. The maximum available power has been
exceeded for too long - e.g. in a very thick
soldering at the high repetition rates.
3. The hot tweezers or cartridge has a short circuit
or an open circuit.
4. Any other trouble preventing the system from
working properly.
The hot tweezers will reset itself automatically should
the cartridge short circuit or go open circuit.
Should the hot tweezers be subject to:
- An electrical surge or the cartridge has not been
fitted correctly.
Please turn the unit off and switch on again to reset.
Sleep function
One of the Series Advanced features is that when
the hot tweezers are placed in the holder, the
temperature at the tip drops automatically to the
sleep temperature. This function is only possible
because of the quick response time which does
not make the user realise the temperature rise
to reach the selected temperature. Also by
this, the oxidation of the tinning of the tip is
considerably reduced and tip life is extended.
To indicate that the hot tweezers are in sleep-
mode, the green led starts pulsing. These
parameters can be modified using the Console
AC 2600 Ref. 2600000.
In order to take advantage of the above
mentioned feature and as a security measure,
it is necessary to place the hot tweezers on
stand when the iron is not being used.
All manuals and user guides at all-guides.com
7
ENGLISH