Error code
"Buzzer sounds on
switching on.
No error code
displayed"
ER03
ER20
ER21
ER22
ER31
ER36
ER47
E2
E3
E4
E5
22
Error codes
Description
The hood command
does not work
Continuous sensor
activation. TC turns off
after 10 sec.
TC internal error
Overheating.
Faulty button
assessment. The user
interface switches off
after 3.5 - 7.5 seconds.
There is an
inconsistency in the
configuration of TC and
induction.
TC internal error
Communication error
between TC and
induction
Cooking area sensor
overheats. TC turns off
after 10 sec.
Wrong pan.
The cooking areas are
Off.
Configuration error. The
cooking area cannot be
activated.
No communication
between UI and
induction generator.
The cooking area cannot
be activated
Possible cause of the
error
LIN cable damaged or badly
connected to the hood
electronic board
Water or pan on glass, on
sensors or on control.
-
The temperature control
has detected a temperature
higher than 85° C.
-
The generator configuration
data do not coincide with
those of the TC.
-
LIN cable damaged.
There is no power supply in
the LIN cable.
Pan empty
The pans are losing their
magnetic characteristics
Internal error in generator
circuits
The induction module is not
configured yet.
LIN cable or power cable
faulty.
Plate cables wrongly
connected.
Internal error in generator or
filter circuits.
Solution
check connection/replace
the LIN cable
Clean the surface of
the control. Remove the
objects from the sensors.
Replace TC.
Leave the hob to cool down
and the error will disappear
when the temperature is
below 75° C.
Check the thermal
insulation.
Replace TC
New configuration.
Replace TC.
Change the generator.
Replace TC.
Replace the Cable.
Check that the Cable has
been inserted properly.
Do not heat empty pans.
Use appropriate pans
Replace the module
Perform manual
configuration.
Check the cables and the
power supply voltage.
Check the cables and the
power supply voltage.
Replace the module.