2.3) Limits of use
Sectional door (Max. H = 2400 mm) (fig. 4)
Counterweight up-and-over door (Max. H = 2400 mm) (fig. 4a)
Overhead spring up-and-over door (Max. H = 2600 mm) (fig. 4b)
4
2.4) Installing SPIDO
1. Connect the draw bar (27) to the curved bar (61) (Fig. 5);
2. Thread the cord (24) into the unthreaded hole of the release pin
and keep it flush at the other end;
3. Tie the two ends together after passing them through the hole in
the knob (25);
4. Insert the guide support bracket (32) into the chain tightening
device and fix it with the screw (48) and the nut (17) (Fig. 6);
5. Insert the slide (23) into the end of the profile (Fig. 7);
6. Insert the screws (35) into the two slots of the profile (Fig. 8);
2.5) Adjusting the drive bar
In order to ensure fine adjustment in the closing manoeuvre, loosen
the bolts of the drive bar with a 10mm wrench and adjust the travel
using the two slots or, if necessary, completely unscrewing the bolts
and changing the fixing position (Fig. 13).
2.6) Fitting the limit switch slides
!
The limit switch slides may only be inserted when the
motor has stopped.
All manuals and user guides at all-guides.com
7. Insert the profile by passing the chain over the motor pinion and
8. Tighten the chain slightly (Fig. 10);
9. Fix SPIDO to the frame of the door (recommended choice) or to
10. Check the measurements for drilling the holes, insert and block
!
To fix the limit switch slides, follow the instructions referring to the
"electrical control unit".
4a
4b
block it with the bracket (33) using two screws (44) (Fig. 9);
the wall with rivets or expansion grips keeping a distance of
between 30mm and 350mm from the maximum travel of the
door (Fig. 11);
the support brackets (18) and fix SPIDO to the ceiling. Cut the
excess part of the bracket (Fig. 12).
Thoroughly tighten all the screw connections.