Mounting and
operating instructions
No. LED
Description
Switch operating mode (speed mode / averaging mode)
3
Q
QA
Press
A
OK
V
The operating mode (speed / averaging) is changed by pressing
N
FS
C
tedly.
Look at the „ZA" LED (red). „ZA" lights = averaging mode is active.
Exit the Set menu (
go to the next setting with the
4
Q
N.O./N.C. switching
QA
Press
A
OK
V
The switching function (N.O/N.C) is changed by pressing
N
FS
C
Look at the „ZA" LED (red): „ZA" lights = switching type N.C. is active.
Exit the Set menu (
go to the next setting with the
5
Activate Factory Setting
Q
QA
Press
A
OK
V
Press
N
FS
C
The sensor is reset to the factory state.
The „ZA" LED lights for confirmation for as long as
Exit the Set mode (
go to the next setting with the
6.4.3 Deactivating the Set Mode (Exit):
First press
, then
. All settings are then saved. The sensor is in the Run mode after releasing the buttons. The
operating indicator „BA" (green) lights steadily
FT 50 RLA Distance sensor - Dokument 068-13799 - Status: 20.09.2005-00
until the „Av" LED lights up.
„ZA" does not light = speed mode is active.
+
) or
Averaging Mode: for detecting rough surfaces. The arithmetic (floating)
average of 100 measured values is taken. This smoothes the measu-
ring result.
Speed Mode: for shortest response time and max. switching frequency
without averaging.
until the „Nc" LED lights.
„ZA" does not light = switching type N.O. is active.
+
) or
until the „FS" LED lights.
once.
+
) or
button.
button..
is pressed.
button.
Factory setting
speed mode
repea-
N.O.
repeatedly.
15