6.4
Make settings
6.4.1 Activating the Set Mode (conf):
Press the buttons „S" and „T" simultaneously for 3 s (or longer) until the LED BA (green) flashes
(LED flashes when time lock open and Set mode activated).
6.4.2 Setting the Sensor
No. LED
Description
1
Set switching point for switching output Q:
Q
QA
Position the object at the desired switching point. The „OK" LED must light.
OK
A
V
Press
N
FS
C
Press
„ZA" LED (red) flashes with 1 Hz.
Exit the Set menu (
go to the next setting with the
Set the switching window for switching output Q:
Position the object at the desired first switching window limit. The „OK" LED
must light.
Press
Press
„ZA" LED (red) flashes with 1 Hz.
Position the object at the desired second switching window limit. The „OK"
LED must light.
Press
the object is detectable and in the operating range. The „ZA" LED lights for
confirmation for as long as
Exit the Set menu (
go to the next setting with the
2
Scaling of the analogue output QA
Q
QA
Position the object at the desired 0% point (4mA). The „OK" LED must light.
A
OK
V
Press
N
FS
C
Press
distance is saved as the 0% point (4mA). The „ZA" LED (red) flashes with
1 Hz.
If no 100% point is to be set, exit the Set menu (
setting with
If a 100% point is to be set, place the object at the desired distance.
The „OK" LED must light.
Press
distance is saved as the 100% point (20mA). The „ZA" LED lights for confir-
mation for as long as
Exit the Set menu (
go to the next setting with the
14
until the „Q" LED lights.
once. If the object is detectable and in the operating range, the
+
) or
until the „Q" LED lights.
once. If the object is detectable and in the operating range, the
once. The distance is saved as the second switching window limit if
+
) or
If the object was not moved after teaching the first switching window
limit, a minimum switching window (1% of the operating range) is laid
around the teach point.
until the „QA" LED lights.
once. If the object is detectable and in the operating range, the
.
once. If the object is detectable and in the operating range, the
is pressed.
+
) or
If the distance between the 0% point is less than 5% of the operating
range, the analogue output is automatically scaled to 5% of the max.
operating range. The middle of the range is placed between the set
0% and 100% points.
button.
is pressed.
button.
+
button.
FT 50 RLA Distance sensor - Document 068-13799 - Status: 20.09.2005-00
operating instructions
Factory setting
Switching window
over the whole
operating range,
i.e. switching output
is active when the
object is in the
operating range and
reliably detected.
Maximum
operating range
) or go to the next