Gas connection
The cooker should be connected to the gas-supply by a gas
safe registered installer. During installation of this product it
is essential to fit an approved gas tap to isolate the supply
from the appliance for the convenience of any subsequent
removal or servicing. Connection of the appliance to the gas
mains or liquid gas must be carried out according to the
prescribed regulation in force, and only after it is ascertained
that it is adaptable to the type
of gas to be used. If not, follow the instructions indicated in
the paragraph headed "Adaptation to different gas types".
On some models the gas supply can be connected on the
left or on the right, as necessary; to change the connection,
reverse the position of the hose holder with that of the cap
and replace the gasket (supplied with the appliance). In the
case of connection to liquid gas, by tank, use pressure
regulators that conform to the regulation in force. The gas
supply must be connected to the left of the appliance.
Be sure that the hose does not pass through the rear of the
cooker touching hot parts.
Adapting to different types of gas
It is possible to adapt the appliance to a type of gas other
than the default type (this is indicated on the rating label on
the cover).
Adapting the hob
Replacing the nozzles for the hob
burners:
1. Remove the hob grids and slide
the burners off their seats.
2. Unscrew the nozzles using a 7mm
socket spanner (see figure), and
replace them with nozzles suited to the
new type of gas (see Burner and nozzle specifications
table).
3. Replace all the components by following the above
instructions in reverse.
Adjusting the hob burners' minimum setting:
1. Turn the tap to the minimum position.
2. Remove the knob and adjust the regulatory screw, which is
positioned inside or next to the tap pin, until the flame is small
but steady. If the appliance is connected to a liquid gas supply,
the bypass screw must be set to a minimum.
3. While the burner is alight, quickly change the position of the
knob from minimum to maximum and vice versa several times,
checking that the flame is not extinguished.
Upon completion of adjustment, reseal using sealingwax or an
equivalent material.
The hob burners do not require primary air adjustment.
After adjusting the appliance so it may be used with a different
type of gas, replace the old rating label with anew one which
corresponds to the new type of gas (these labels are available
from Authorised Technical Assistance Centres).
Should the gas pressure used be different (or vary slightly) from
the recommended pressure, a suitable pressure regulator must
be fitted to the inlet hose in accordance with current standards
EN 88-1 and EN 88-2 relating to "regulators for channelled gas".
Replacing the Triple ring burner nozzles
1. Remove the pan supports and lift the burners out of
their housing. The burner consists of two separate
parts (see pictures).
2. Unscrew the nozzles using a 7 mm socket spanner.
Replace the nozzles with models that are configured
for use with the new type of gas (see Table 1). The
two nozzles have the same hole diameter.
3. Replace all the components by completing the
above operations in reverse order.
• Adjusting the burners' primary air :
Does not require adjusting.
• Setting the burners to minimum:
1. Turn the tap to the low flame position.
2. Remove the knob and adjust the adjustment screw,
which is positioned in or next to the tap pin, until the
flame is small but steady.
3. Having adjusted the flame to the required low
setting, while the burner is alight, quickly change the
position of the knob from minimum to maximum and
vice versa several times, checking that the flame
does not go out.
9