USE AND MAINTENANCE
IMPORTANT!
The warranty is void if the gun is used without the
protective cuff, and if this results in joint filler get-
ting onto the piston rod.
The gun must NOT be used with a nozzle in which
joint filler has set or hardened. The nozzle must then
be replaced or cleaned of the set or hardened joint
filler. The nozzle size must be at least 3.5mm – see
instruction page 5.
USE AND MAINTENANCE
REPLACEMENT OF PROTECTIVE CUFF
1. Pull the cuff backwards over the piston rod
2. Reveal the toothed bar, and unscrew the screw.
3. Pull off the piston joint, and then the cuff may be
pulled off the piston rod
REPLACEMENT OF PISTON
(TUBE/CARTRIDGE)
1. When the gun is used for cartridges the tube
piston should not be fitted
2. The tube piston is clicked off the piston joint as
shown in the picture. When the gun is used for
tubes, the tube piston must be fitted
All manuals and user guides at all-guides.com
ALWAYS return the piston rod before removing the
cylinder.
Do NOT force back the piston rod with the packaging
(sachet/cartridge)
Contact the dealer where you bought the gun if repair
is necessary.
4. Push down the new cuff along the piston rod, and
reassemble the piston joint by pushing it into place
on the piston rod and tighten the screw.
5. Put the protective cuff in place by pushing it towards
the piston as shown. Check that it is fitted tightly.
3. The tube piston can be clicked on and off when the
piston rod is fully returned

Publicité