LOCATING MALFUNCTIONS
The device has a LED on the push button to inform about alarms.
LED STATUS
Color
TIME
TIME
LED
ON
OFF
Off
0
Green
Fixed
30 ms
Blue
600 ms
2 flashes
Red
200 ms
200 ms
15 ms
Red
600 ms
4 flashes
15ms
Red
600 ms
6 flashes
15ms
Red
600 ms
3 flashes
15ms
Red
600 ms
5 flashes
600ms
Red
60 sg
3 flashes
600ms
Red
60 sg
3 flashes
LED status: depends on battery
charge. See point 4.4, page 10
•
1000ms = 1 second
When a failure warning occurs, press ON/OFF button to reset the alarm.
6
INSTRUCTIONS TO ORDER SPARE PARTS
6.1 INSTRUCTIONS TO ORDER SPARE PARTS
1.- Every spare parts order must include PART CODE NUMBER AS STATED IN THE PARTS
LIST. We recommend including the MACHINE SERIAL NUMBER.
2.- The identification plate with serial and model number is located as shown in the point 2 of this
manual.
3.- Let us to know the right shipping instructions, including the wished route, the address and the
full name of the consignee.
4.- Do not return the parts without authorisation, the return is done with freight prepaid.
DESCRIPTION
Normal functioning. Status:
Waiting
Normal functioning. Status:
Working
Status: Low battery
Output overload
Overheating warning
Battery overvoltage
Short circuit
Incorrect battery voltage
WITH OPEN DOOR
Status: waiting and door
open.
Status: in working order and
door open
Status: running with the
door open and discharged
battery.
BATTERY POWERED ELECTRONIC CONVERTER
ACTION TO TAKE
None
None
Charge the battery
Excess load connected to the converter or
problem with the connected vibrator.
Clean casing (housing).
If the warning remains contact the official
service.
Send the device to the official service or a
dealer for checking.
Defective poker.
Defective converter.
Contact technical service
Close the door
Closet he door
Charge battery and close door