6.0 electrical information
electrical information
EN
6.1
hard wiring connection
It is necessary to hard wire this appliance.
Permanently framing the appliance with an enclosure, requires the appliance junction box to be hard wired.
This appliance must be electrically connected and grounded in accordance with local codes. In the absence of
local codes, use the current CSA C22.1 Canadian electrical code in Canada or the ANSI/NFPA national electrical
code in the United States.
6.2
receptacle wiring diagram
6.3
electronic wiring diagram
WARNING
!
Do not use this appliance if any part has been under water. Call a qualifi ed service technician immediately to
have the appliance inspected for damage to the electrical circuit.
Risk of electrical shock or explosion. Do not wire 110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.
All wiring should be done by a qualifi ed electrician and shall be in compliance with local codes. In the
absence of local codes, use the current CSA22.1 Canadian Electric Code in Canada or the current National
Electric Code ANSI/NFPA NO. 70 in the United States.
Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door opened or
removed.
30
W415-4020 / 08.09.21
ELECTRICAL
BOX
3 PRONG
RECEPTACLE
note:
Ensure that the transformer is plugged into the receptacle.
CABLE
L1
CONNECTOR
(BLACK)
GROUND
L2
(GREEN)
(WHITE)
WIRE
NUTS
43.1

Publicité