4. Control Panel and LCD Operations
Messages in the LCD
Warning! Parallel UPS Config. Wrong Parallel UPS Configure error.
Warning! Battery Voltage Low
Warning! ID Conflict
Pre-Alarm! Line Voltage Fail
Pre-Alarm! Line Voltage Normal
Pre-Alarm! Line Frequency Unstable
Pre-Alarm! Line Frequency Normal
Pre-Alarm! Over Load
Pre-Alarm! Load Normal
Pre-Alarm! Load Unbalance
4.4 History Record
Table 4.13: Warning List For Changing Important Settings
Item No.
Description
1
Setup! Model Name
3
Setup! Language
5
Setup! Adjust Time
7
Setup! System Installed Date
9
Setup! System Last Maintain Date
11
Setup! Battery Installed Date
13
Setup! Battery Last Maintain Date
15
Setup! Change Password
17
Setup! Baud Rate
19
Setup! Audible Alarm
21
Setup! Factory Reset
23
Setup! EEPROM Reset
25
Setup! EPO Function
27
Setup! Save Setting
29
Setup! Power Rating Setting
31
Setup! Nominal Battery Voltage
33
Setup! Maximum Charging Current
35
Setup! Battery Low Capacity
37
Setup! Periodic Battery Test
39
Setup! BATTERY Age Alert
41
Setup! Charging Voltage
43
Setup! UPS Parallel
45
Setup! Auto-Restart Battery Voltage
Table 4.14: UPS Mode Changes
Item No.
Description
1
UPS Mode! Power On Mode
3
UPS Mode! Bypass Mode
5
UPS Mode! Battery Mode
7
UPS Mode! Fault Mode
9
UPS Mode! ECO Mode
11
UPS Mode! Un-Connection
Table 4.15: Control Action Execution
Item No.
Description
1
Control! System Turn On
3
Control! Manual Battery Test
5
Control! Turn To Bypass
7
Control! Cancel Shutdown
9
Control! Charger Turn Off
Explanation
Battery voltage is too low.
Power stage ID in conflict.
Line voltage over range.
Line voltage recovered to normal.
Line frequency over range.
Line frequency recovered to normal.
Output Load over range.
Output Load recovered to normal.
Output Load unbalance.
Item No.
Description
2
Setup! Turn On Password
4
Setup! Change Turn On Password
6
Setup! Nominal Power Display
8
Setup! Output Voltage
10
Setup! Bypass Voltage Range
12
Setup! Bypass Frequency Range
14
Setup! Converter Mode
16
Setup! ECO Mode
18
Setup! Bypass Mode
20
Setup! Auto-Restart
22
Setup! Cold Start
24
Setup! Battery Mode Delay Time
26
Setup! Shutdown Restore Time
28
Setup! Redundancy
30
Setup! Charger Test
32
Setup! Battery Capacity in Ah
34
Setup! Battery Low Voltage
36
Setup! Battery Shutdown Voltage
38
Setup! Stop By Time
40
Setup! Temperature Compensation
42
Setup! PRE-ALARM
44
Setup! Independent Battery
Item No.
Description
2
UPS Mode! Standby Mode
4
UPS Mode! Line Mode
6
UPS Mode! Battery Test Mode
8
UPS Mode! Converter Mode
10
UPS Mode! Shutdown Mode
Item No.
Description
2
Control! System Turn Off
4
Control! Cancel Battery Test
6
Control! Shutdown Restore
8
Control! Charger Turn On
41