COMMUNICATION Screen
Settings are made for the control signal-connecting terminals on the back.
If the setting is changed, be absolutely sure to switch on the power again.
Item
STYLE
This sets a communication system according to the
system used.
P TO P (Point to point)
This is set when a remote control unit controls a camera.
M.DROP (Multi-drop)
This is set when a remote control unit controls a plural
number of cameras.
This is set when the STYLE item is set to M.DROP. This
MACHINE ID
is the number that identifies individual cameras in a group.
No proper function can be realized if an ID number is
repeated within a system.
A combined use with the RM-P2580 necessitates the
setting together with the video input number of the RM-
P2580.
If the item STYLE is set to P TO P, "- - -" will appear, and
settings cannot be changed.
[Set values: 1 to 99]
FACTORY SETTINGS Screen
Set values are returned to initial values.
Item
The values set on the menu are returned to initial values.
FACTORY
CANCEL
SETTINGS
CLEAR
(WITHOUT TITLE)
CLEAR (ALL)
Select respective set value and press the SET button. Then,
"DATA CLEARED" will appear for about 3 seconds. Be
sure not to switch off the power while the display is still on.
However, when FACTORY SETTINGS by means of
transmitted commands, the contents of the
COMMUNICATION menu do not return to the factory
settings.
All manuals and user guides at all-guides.com
Functions and set values
Functions and set values
: No return to the initial value.
: Returns set values except titles to the
initial value.
: Returns all set values including titles
to the initial value.
MEMO
Initial value
P TO P
– – –
Initial value
–
E-35