CONNECTION/INSTALLATION
Auto white balance control adjustment
Each light source has its own colour temperature. Therefore, when the main light source
lighting an object is changed, the white balance should be adjusted again by pressing the
AWC button.
AWC button
SET
AWC
MENU
AWC
OPERATION
DURING OPERATION
AWC
NG : OBJECT
OBJECT ERROR
AWC
ERROR : HIGH LIGHT
OVER LIGHTING
E-22
All manuals and user guides at all-guides.com
CAMERA
SETUP
EXT TERM-OFF
ON
INT/GL
LL
DUPLEX
SIMPLEX
RX TERM-OFF
ON
NOT USED
IRIS
VIDEO
DC
AWC
OK
DISPLAYING RESULT
AWC
ERROR : LOW LIGHT
LOW LIGHTING
1.
Place a white object under the same
lighting condition as the object to be shot
and zoom in to fill the screen with white.
2.
When the AWC button is pressed for
approx. one sec., the white balance is
adjusted for the object being recorded.
3.
During the time when the Auto White
function is operated, "AWC OPERA-
TION" is displayed (for approx. 0.5 sec.).
When the appropriate white balance is
acquired, "AWC OK" is displayed.
4.
Error message display
● NG : OBJECT
Displayed when there is not enough
white colour on an object or the colour
temperature is not suitable.
By taking a shot of a white object to
fill the screen, adjust the white balance
again.
● ERROR : LOW LIGHT
Displayed when the light is low. In-
crease the illumination then re-adjust
the white balance.
● ERROR : HIGH LIGHT
Displayed when the light is too bright.
Decrease the illumination then re-ad-
just the white balance.
MEMO
Even if you press the AWC button, the white
balance will not be re-adjusted during the
operation in the black-and-white mode.