EN
E-PAK 150 DX/300 DX/500 DX
Motor
Voltage
power
and
(kW/hp)
frequency
(V)/(Hz)
3.45/5
230/60
3.45/5
440/60
3.45/5
460/60
3.45/5
575/60
6
Main components
Figure 5 shows the main components of E-PAK 150 DX/300 DX/500 DX.
These are as follows:
1.
Filter cleaning device.
2.
Control filter.
3.
Start and control unit and control panel.
4.
Dust collector.
5.
Vacuum limiting valve.
6.
Thermal switch, 125 °C (257 °F), with automatic reset.
7.
High-pressure side channel fan.
8.
Pressure switch.
9.
Outlet silencer.
10.
Outlet.
11.
Main filter.
12.
Explosion relief panel (not on E-PAK 150 DX/300 DX/500 DX intended
for a suppression system).
NOTE!
bend the membrane or frame.
13.
Flanged inlet.
14.
Collector bin with antistatic plastic bag.
NOTE!
Nederman original bags only.
15.
Acoustic enclosure.
16.
Detection device (suppression system only), see Figure 5b.
17.
Action element (suppression system only), see Figure 5b.
6.1
Start and control unit
E-PAK 150 DX/300 DX/500 DX has a start and control unit, see Figure 10. For
information about the different terminals, see the terminal connection diagrams
in Figure 23 (E-PAK 150 DX) and Figure 24 (E-PAK 300 DX/500 DX).
NOTE!
E-PAK 150 DX has a simplified start and control unit without Y/D
connectors and Y/D timer.
30
All manuals and user guides at all-guides.com
Nom.
F1
F2 &
F4,
current
Recom.
F3,
slow
(A)
mains
slow
(A)
fuses,
(A)
slow (A)
12.6
25
6
4
7.7
15
6
4
7.3
15
6
4
4.95
15
6
4
The explosion relief panel is to be handled with great care. Never
Never use the unit without the antistatic plastic bag! Use
F5 &
S1F Over-
Min.
F6,
load relay
cable
fast
setting
area to
(A)
(A)
motor
(mm
) Z
2
1
12.6
2.5
1
7.7
2.5
1
7.3
2.5
1
4.95
2.5
Cable
Cable
area
area
inside
inside
starter
starter
(mm
) V
(mm
) X
2
2
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5