All manuals and user guides at all-guides.com
Universal access, resetting codes
If you have forgotten your master code, or it no longer seems to
function, then perform the following steps.
- Remove your code lock from the power supply
- Move jumper DAP (8) from „OFF" to „ON"
- Reconnect the main power supply to your code lock (a perma-
nent beep sounds)
- Now move jumper DAP (8) from „ON" to „OFF" (the beep tone
mutes) The master code has now been reset to „0000".
- You are now in programming mode and can make all required set-
tings. Please take these settings from the chapter „Programming
explanation" in this instruction.
Optical and acoustic indication
Status:
1. In Programming mode
2. switch operations
3. correct Code-entree
4. Wrong Code-entry
5. DAP-Jumper is while
of the mains voltage on
„ON"
6. standby mode
7. Output is activated
The entry and activation sounds can be switched on and off (see
programming mode 81 and 83).
56
Beeper:
off
1 x beeping
2 x beeping
5 x beeping
permanent
beeping at the
Base station
off
1s Beep sound
„MAIN" LED:
illuminates
flashing 1 x
flashing 2 x
flashing 5 x
all two seconds
a flashing
all two seconds
a flashing