DU OUT
O/P 1 INHIB.
INT LOCK
OUTPUT 2
DOOR SENSE
By using a magnetic switch the
entrance door can be observed and
programmed.
A) Door operating alarm: Alarm when
the door is opened by force without
access code or door opening. The
alarm is activate for about 60 seconds and can be switched off
with the user code 1 or one of the codes of the user group 1. Pro-
gramming mode 80
B) Door alarm when exceeding the free programmed opening time
between 1 and 999 seconds. Programming mode 9
50
„DURESS" coercion contact -
switches to ground potential if an incorrect code
was entered 10 times during programming (71).
Output 1 access control.
NPN switched output that switches to the minus
potential (-) for 5 seconds when a correct user
code is entered. In a two-door system this can
be used to avoid both doors being opened at the
same time (two code locks required)
Switching output 2
N.C.: Opener contact (N.C./COM)
COM: combinated Connection
N.O.: Closing contact (N.C./COM)
this contact