Detecting Live Wires
The Live Wire Detection feature is always on and the
"Live Wire" icon will be displayed on the LCD. When a
Live Wire is detected, the red live wire LED indicator
will be on.(see illustration 3 & 4)
Static electricity charges that can develop on drywall
and other surfaces will spread the voltage detection
area many inches to each side of the actual electrical
wire. To aid in locating the wire position, scan holding
the unit 1/2 inch away from the wall surface or place
other hand on surface approximately 12 inches from
sensor.
Warning: shielded wires or live wires in metal
conduits, casings, metalized walls or thick, dense
walls, will not be detected. Always turn AC power
off when working near wiring.
The IntelliL L a a s s e e r r
(for USA version) and 230 volts for (European version)
AC in live electrical wires. It will also detect the
presence of live wires having greater than 230 volts.
Cautions on Operating
You should always use caution when nailing, cutting or
drilling in walls, ceilings and floors that may contain
wiring or pipes near the surface. Shielded, dead or
non-powered wiring will not be detected as live
wires. Always remember that studs or joists are
normally spaced 16 inches or 24 inches apart and are 1-
1/2 inches in width. To avoid surprises, be aware that
anything closer together or of a different width may be an
additional stud, joist or fire break.
When working near AC electrical wires, always
turn off the power.