Putting into Operation
plate of the unit. Extension cords must have a conductor cross section of 2 x 1.5 mm
: Set the switch
: Set the switch
controller
as required.
: Set the switch
gram or program the temperature and air flow
as required (see "Settings").
Adjusting the Settings on the Display 2
Begin the selection with the SELECT pushbutton (menu). Note: When an indication flashes in the display, a
change can be initiated with either PLUS or MINUS. Repeated actuation of SELECT leads to the next step.
2 sec
1 x
1. 1-Free setting
2. 2-Free setting
3. Shrinking
4. Forming
5. Soldering copper
6. Drying paint
7. Paint stripping
The keyword of the selected function program is indicated by flashing. Longer text begins to move after 2 sec-
onds and returns to the keyword after 2 passes. Within this period, the SELECT pushbutton can be pressed
again to adjust the temperature or the air flow.
– Select STANDBY when interrupting your work for short time. The energy absorption is reduced.
– At the end of your work, always select COOL DOWN. When the unit has cooled off, switch it off and pull
the plug from the receptacle.
The voltage of the power source must agree with the value given on the name-
to I or II.
to I or II. Set the temperature
to I. Select the desired pro-
1 x
1 x
80 °C/5
80 °C/5
450 °C/5
500 °C/4
650 °C/3
650 °C/5
425 °C/5
- 6 -
Set the switch
to 0.
To cool the unit off, set the switch
perature controller
to MIN. When the unit has
cooled off, set the switch
To cool off the unit, have it operate on COOL
DOWN (see "Settings").
When the unit has cooled off, set the switch
1 x
1 x
8. Welding PPEPDM
9. Welding HD-PE
10. Welding PP
11. Welding PVC-U
12. Welding ABS
13. Welding PC
14. Welding floor-foil
2
min.
to II and the tem-
to 0.
to 0.
1 x
280 °C/5
300 °C/3
320 °C/3
340 °C/3
360 °C/3
370 °C/3
450 °C/3