● Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person
competent in the use of flammable refrigerants.
● Appliance should be installed, operated and stored in a room with a floor area larger than the one indicated in the chart .
Quantity of R290 gas in charge
(see rating label on the appliance)
152≦m≦185
186≦m≦225
226≦m≦270
271≦m≦290
WARNING: System contains refrigerant under very high pressure. The system must be serviced by qualified persons only.
1. Transport of equipment containing flammable refrigerants (Annex CC.1)
Compliance with the transport regulations.
2. Marking of equipment using signs(Annex CC.2)
Compliance with local regulations.
3. Disposal of equipment using flammable refrigerants(Annex CC.3)
Compliance with national regulations.
4. Storage of equipment/appliances (Annex CC.4)
The storage of equipment should be in accordance with the manufacturer's instructions.
5. Storage of packed (unsold) equipment(Annex CC.5)
Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of
the refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
6. Information on servicing(Annex DD.3)
1) Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is
minimised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
2) Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is
being performed.
3) General work area
TCL Air Conditioner Service Manual
(g)
m<152
Minimum size of the site for use and storage
(m²)
4
9
11
13
14
4