DIP switch ON: RC communication is always enabled.
DIP switch OFF:
RC
communication
(default factory)
When an activation signal is applied to the RC input of the terminal block, RC is enabled.
IMPORTANT:
Turn dipswitch 7 "OFF" after installation and when leaving the site for security reasons. This will prevent
unauthorized use of a remote control unit that may be used to disable the detector.
8-9
DIP switches OFF
NOTE:
See Set Terminal Blocks for activation details.
BUS Mode Configuration (DIP
switch 6=ON):
MODE
DIP switch
Description
Number
Used to set the detector ID number. (See Table 1)
1-5
Set the ID number in the same way as for any other ProSYS accessory.
Used to determine the detector's connection mode.
6
DIP switch ON: ProSYS connection – BUS configuration
NOTE:
24
depends on the voltage applied to the terminal block
BUS ADDRESS