All manuals and user guides at all-guides.com
Tamper indication in the Relay or
BUS mode
Walk test cannot be initiated via the
ProSYS keypad
Green LED doesn't operate during
Walk test - MW channel does not
function
Specifications
Coverage
Variable Mounting Height
RFI immunity
Tamper probably
Visually verify that ceiling tamper and
not closed
spring are correctly installed
Wrong code
Insert the appropriate code
Ind. LuNAR
Normal behavior
RK200DTG3 is
configured (via the
ProSYS) to the
"MW disable on
DISARM"
during ProSYS's
DISARM mode
Ind. LuNAR
Reset the detector.
RK200DTG3
If MW channel trouble reoccurs, replace
operating
in
the detector with a new one
Bypass
mode
due to "Bypass
MW
channel
mode"
Coverage pattern consists of 192 fingers (96 Fresnel facets) divided
into 3 lens sections.
Each lens section has 4 adjustable vertical positions for variable
mounting height and customized coverage.
360° by 18m (60ft) diameter. When mounting the detector under
3.7m, the coverage diameter starts to decrease up to 15m (50ft).
From 2.7m to 8.6m (9' to 28'), 4 lens positions according to installation
height
According to EN50130-4
Ind. LuNAR RK200DTG3 Installation Guide
31