WARNING
CAUTION
INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of the door at a
minimum height of 5 feet where small children cannot
reach, and away from moving parts of the door and
door hardware. The installation surface must be
smooth and flat. If installing into drywall (Figure 1),
AVERTISSEMENT
drill 5/32" holes and use anchors provided. For pre-
wired installations (as in new home construction), it
may be mounted to a single gang box (Figure 2).
NOTE: After installation, a green or amber indicator
ATTENTION
light behind the cover will indicate proper connection.
If not lit, the Lock and Light features will not function
(reverse wires to correct).
1. Strip 7/16" of insulation from one end of bell wire
and connect to the two screw terminals on back of
door control by color: white wire to WHT and
white/red wire to the RED (Figure 3).
2. Remove white cover by gently prying on a side
corner near the top of the cover with a small flat
head screwdriver (Figure 4). Fasten with
6ABx1-1/4"self-tapping screws (drywall installation)
or 6-32x1" machine screws (into gang box) as
follows:
• Drill and install bottom screw, allowing 1/8" to
protrude above wall surface.
• Position bottom of door control on screw head
and slide down to secure. Adjust screw for snug
fit.
• Install top screw with care to avoid
cracking plastic housing. Do not overtighten.
• Insert bottom tabs and snap on cover.
NOTE: The push bar may stick if the door control is
not mounted on a smooth surface. If a click is not
heard when pressing the push bar, loosen the two
mounting screws or relocate the door control to a
smoother surface.
3. (Standard installation only) Run bell wire up wall
and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do not
pierce wire with a staple, creating a short or open
circuit.
4. Strip 7/16" of insulation from end of bell wire.
Connect bell wire to the quick-connect terminals as
follows: white to white and white/red to red
(Figure 5).
NOTE: When connecting multiple door controls to the
opener, twist same color wires together. Insert wires
into quick-connect holes: white to white and red/white
to red.
5. Use tacks or staples to permanently attach
entrapment warning label to wall near door control,
and manual release/safety reverse test label in a
prominent location on inside of garage door.
NOTE: DO NOT connect the power and operate the
opener at this time. The trolley will travel to the full
open position but will not return to the close position
until the sensor beam is connected and properly
aligned. See Safety Reversing Sensor Instructions
beginning on page 21.
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
AVERTISSEMENT
• Install door control within sight of garage door, out of
reach of children at a minimum height of 5 feet, and away
from all moving parts of door.
AVERTISSEMENT
• NEVER permit children to operate or play with door control
push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
HARDWARE SHOWN ACTUAL SIZE
6AB x 1-1/4" Screw
(drywall installation)
6-32 x 1" Screw
(gang box installation)
STANDARD
Figure 1
INSTALLATION
To Replace
Insert Bottom Tabs First
Figure 3
MULTI-FUNCTION
DOOR CONTROL (BACK)
Top Mounting Hole
Terminal
Screws
RED
WHT
Bell Wire
Bottom Mounting Hole
Figure 5
9
1
9
1
7
3
7
3
5
5
KG
KG
18
WARNING
WARNING
Insulated
Staples
Dry Wall Anchors
PRE-WIRED
Figure 2
INSTALLATION
Single
Gang Box
24 Volt
To Replace
Bell Wire
Insert Bottom Tabs First
Figure 4
REMOVE COVER
Door Control
To release wire, push in tab
Connections
with screwdriver tip
White
Red
Black
7/16"
Strip wire 7/16"