! If the card is set to the stand-by mode, the min. / max. temperature memorized and any alarms will
not be saved
.
BLACKOUT ALARM
OPEN DOOR ALARM
In the event of a door open the display will visualise the [dA] label alternating with the current visualisation
while the buzzer, if present, will signal the event acoustically with a beep of the duration of 5 seconds
repeated every 10 seconds.
The alarm will reset upon the closure of the door and is registered in memory (high frequency flashing
defrost LED).
HIGH CONDENSATION TEMPERATURE ALARM
If the condensation temperature is too high, due to dirty condenser, the label [HtC] and the room temperature
alternate on the display.
The buzzer sounds.
The buzzer can be turned off by pressing the key
The visual warning signal stays on until the condensation tempertaure returns to normal range.
Defrost may be either manual type or automatic type.
Manual defrost
Models +2°C / +10°C, -20°C / +5°C, +14°C / +16°C
The defrosting process can be stopped manually by pressing the "up" key again for 4 seconds. When the
process is stopped, a signal blinks on the label display [ndF].
Models -25°C / -15°C
In the -25°C / -15°C models, the defrost function must be activated by the user whenever a thick layer of
frost accumulates upon the shelves. In order to defrost the unit, turn it off by setting the panel to stand-by
mode, then open the door and remove the products. Remove the cap on the bottom and wait for all the frost
to melt. Use a sponge to direct all the water on the bottom into the drain hole. Clean the unit's interior
surfaces with a dry cloth and replace the cap on the bottom.ù
The defrost led blinking at high frequency indicates a blackout
Pushing the on/sby/enter button the [bLO] label will be visualised on the
display.
Pushing the on/sby/enter button the maximum temperature recorded in the
chamber will be visualised on the display.
Pushing the on/sby/enter button the defrost led is reset to standard operation.
The display shows [rES] after the abnormal event.
Push the button up for 4 sec seconds to immediately activate the defrost
cycle.
Just before the defrosting process begins, the temperature of the blocked cell
is displayed.
.
18
DEFROSTING