PARAMETERS OF CONFIGURATION
Parameter
Room probe calibration (the parameter is expressed in eighths of degree)
/1
digital input configuration (0 = open contact, 1 = closed contact)
/6
door open alarm delay time (0 = excluded)
/7
room probe reading
Pr
condenser probe reading
Pc
adjuster hysteresis (differential)
r0
min. operating setpoint selectable
r1
max. operating setpoint selectable
r2
compressor activation delay from device start
C0
min. delay between compr. stop and subsequent start
C2
compressor start cycle time in the event of room probe alarm
C5
C5 % where compr. starts in the event of room probe alarm
C6
defrost interval (0= excluded)
d0
max. defrost duration (0= defrost never activated)
d3
defrosting display (0=actual cell temperature,
d6
1=stopped cell temperature, 2=dEF label)
defrost interval count:
dE
0= actual hours; 1=hours comp. ON; 2= autodeterm.
alarm hysteresis (differential)
A0
min. operating setpoint alarm (0= excluded)
A1
max. operating setpoint alarm (0= excluded)
A2
alarm exclusion from device start
A3
buzzer activation mode for alarm : 0= always; 1= timer-controlled
A4
time limit for buzzer acoustic signal (only if A4 = 1)
A5
temperature alarm exclusion time (only if A1 and/or A2 0)
A6
evaporator fan func. during regular operation (0=OFF; 1=ON; 2=parallel with compressor)
F3
temperature below which the condenser fan turns off
F6
condenser fan differential (relating to F6)
F7
condenser fan func. during regular operation (0=parallel with compr.; 1=ON); also refer to F6 and F7
F8
critical temperature for signalling high condensation temperature
FA
critical temperature for high pressure akarm
Fb
Parameter
Room probe calibration (the parameter is expressed in eighths of degree)
/1
evaporator probe activation (0=off;1=on)
/2
condenser probe activation (0=off; 1=on)
/3
digital input configuration (0 = open contact, 1 = closed contact)
/6
door open alarm delay time (0 = excluded)
/7
setpoint attivazione resistenza porta (solo se /9 = 0)
/A
door resist. activation adjustment hysteresis (only if /9 =0)
/b
Sensor probe visualisation management (0 = normal, 1 = limited from above r0)
/E
room probe reading
Pr
defrost/evaporator probe reading
Pd
condenser probe reading
Pc
adjuster hysteresis (differential)
r0
min. operating setpoint selectable
r1
max. operating setpoint selectable
r2
Press the on/sby/enter key to confirm your selection.
Description
MEASUREMENT INPUTS
COMPRESSOR ADJUSTMENT
COMPRESSOR PROTECTION
DEFROST
ALARMS
EVAPORATOR FAN ADJUSTMENT
Description
MEASUREMENT INPUTS
COMPRESSOR ADJUSTMENT
12
"UNITS +2°C/+10°C"
Default
min
MAX
0°C
-40
+99
1
0
1
120 sec
0
240
- °C
-
-
- °C
-
-
+4°C
1
15
+2°C
-40
r2
+10°C
r1
+99
1 min
0
240
3 min
0
240
10 min
1
240
50 %
0
100
6 hours
0
99
20 min
0
99
1
0
2
0
0
1
+2 °C
1
15
-2 °C
-40
0
+15 °C
0
+99
120 min
0
240
1
0
1
1 min
0
240
15 min
0
240
1
0
2
20°C
-40
+99
+3°C
1
25
0
0
1
46°C
-40
+99
49°C
-40
+99
"UNITS -25°C/-15°C"
Default
min
MAX
-16°C
-40
+99
0
0
1
1
0
1
0
0
1
120 sec
0
240
-7°C
-40
+99
2°C
1
15
1
0
1
- °C
-
-
- °C
-
-
- °C
-
-
+2°C
1
15
-25°C
-40
r2
-15°C
r1
+99