adjuster hysteresis (differential)
r0
min. operating setpoint selectable
r1
max. operating setpoint selectable
r2
Relative humidity adjustment hysteresis (differential)
r3
Dead zone relative humidity adjustment
r4
Relative humidity adjustable minimum setpoint
r5
Relative humidity adjustable maximum setpoint
r6
compressor activation delay from device start
C0
min. delay between compr. stop and subsequent start
C2
compressor start cycle time in the event of room probe alarm
C5
C5 % where compr. starts in the event of room probe alarm
C6
defrost interval (0= excluded)
d0
max. defrost duration (0 = the defrosting function will not star)
d3
defrosting display (0=actual cell temperature, 1=stopped cell temperature, 2=dEF label)
d6
defrost interval count: 0= actual hours; 1=hours comp. ON; 2= autodeterm.
dE
alarm hysteresis (differential)
A0
min. operating setpoint alarm (0= excluded)
A1
max. operating setpoint alarm (0= excluded)
A2
alarm exclusion from device start
A3
Buzzer alarm activation modality (0 = always; 1 = timed)
A4
Time limit for alarm buzzer acoustic notification (only if A4 = 1)
A5
temperature alarm exclusion time (only if A1 and/or A2 0)
A6
evaporator fan func. during regular operation (0=OFF; 1=ON; 2=parallel with compressor)
F3
temperature below which the condenser fan turns off
F6
condenser fan differential (relating to F6)
F7
condenser fan func. during regular operation (0=parallel with compr.; 1=ON); also refer to F6 and F7
F8
condenser fan func. during defrost and dripping (0=OFF; 1=ON, 2=ON if Tc≥35°C and OFF if
F9
Tc<33°C)
critical temperature for signalling high condensation temperature
FA
critical temperature for high pressure akarm
Fb
COMPRESSOR ADJUSTMENT
COMPRESSOR PROTECTION
EVAPORATOR FAN ADJUSTMENT
USER PARAMETER CONFIGURATION - PROBE READING
Push the up and down buttons simultaneously and hold down for more than 3
seconds.
The label [Loc] is visualised.
Utilise the up and down buttons to scroll the sensor probe readings and the
user parameters.
Press the on/sby/enter key to confirm your selection and enter the mode for
reading probes or changing parameters.
The current value blinks on the display.
Use the keys
Press the on/sby/enter key to exit or confirm the selection of the parameter
new value; the setting stops blinking.
DEFROST
ALARMS
to select the new value, applicable to parameters only.
15
+4°C
1
15
+14°C
-40
r2
+16°C
r1
+99
5%
0%
15%
1%
0%
10%
40%
20%
80%
50%
20%
80%
1 min
0
240
2 min
0
240
10 min
1
240
40 %
0
100
0 hours
0
99
5 min
0
99
1
0
2
0
0
2
+2 °C
1
15
-2 °C
-40
0
+15 °C
0
+99
120 min
0
240
1
0
1
1 min
0
240
60 min
0
240
1
0
2
20°C
-40
+99
+3°C
1
25
0
0
1
2
0
2
41°C
-40
+99
44°C
-40
+99