FORCED MANUAL DEFROST
CHANGE IN RELATIVE HUMIDITY +2°C/+10°C and -20°C/+5°C
CHANGE IN RELATIVE HUMIDITY +14°C/+16°C
TEMPERATURE SETPOINT SETTING/VARIATION
Press and release the key on/sby/enter: the current setpoint blinks on the
display for 5 seconds.
After 5 seconds, the displays shows the room temperature again
While the display is blinking, use the up and down keys to increase or
decrease the temperature setpoint
Press the on/sby/enter button again to confirm the new set point
SMART FUNCTIONS – Quick-access functions
Push the up button, hold down for more than 3 seconds to access the manual
defrost functions.
Push the down button, hold down for more than 3 seconds to modify the
percentage of relative humidity in the chamber.
The temporary flashing confirmation label [F_C] corresponds to a too low
relative humidity (fans in parallel with the compressor).
The flashing temporary confirmation label [F_ _] corresponds to a too high
relative humidity (fans independent).
The relative humidity that blinks on the temporary label [FtE] is programmed
by the manufacturer.
Push the down button and hold down for more than 3 seconds: the display
visualises the current humidity setpoint for 5 seconds in a flashing modality.
Once that time has elapsed the display returns to the indication of the
temperature in the cell.
During the flashing mode on the display use the
decrease the humidity setpoint desired.
Push the on/sby/enter button to confirm the new setpoint: the acquisition of
the new value is signalled by an acoustic emission of 3 short consecutive
beeps.
After 2 seconds the display returns to the indication of the temperature in the
cell.
Push the up and down buttons simultaneously and hold down for more than 3
seconds.
The label [Loc] is visualised.
BLOCKIEREN DER TASTATUR
10
buttons to increase or