3.4 Arc Length Adjustment (ArC)
When button 9 is pressed for 3 seconds, arc length function will be active. The factory setting is 0.0. You can
change the arc length setting in the range of +7/-7 by turning the existing button left and right. In the change
made towards +7, the wire contact approaches the nozzle and the arc length becomes longer. In the change
made towards -7, the wire approaches the weld metal and the arc length becomes shorter. After the desired
setting is made, the current button is pressed once to exit the setting.
3.5 MIG Curve
Set Voltage
Voltage 0 / 25
Set Voltage
Voltage 0 / 25
Set Wire
Set Wire
Pre-Gas
Post Gas
Burn Back
Arc On Time
Arc Off Time
Wire Diameter
Thickness
Gas Type
Wire Type
Crater
Mode
Trigger
Method
www.magmaweld.com
Slow Release
On
Crater Open
Pre Gas
Slow Release
On
Crater Open
Pre Gas
Slow Release
Wire 0 / 25
Off
Crater Closed
Pre Gas
Slow Release
Wire 0 / 25
Off
Crater Closed
Pre Gas
Pnt Mode
On
Pnt Mode
Spot
Off
Pre Gas
Value Range
0,0 - 9,9 sec
0,0 - 9,9 sec
25 - 0 - 25
0,2 - 9,9 sec
0,0 - 9,9 sec
0,6 - 2,4 mm
0,6 - 20,0 mm
CO₂, Ar/5-10 CO₂, Ar/15-25 CO₂, Ar/2.5 CO₂, Ar/10-15 CO₂, Argon
Steel, AlMg, FCW, AlSi, FCW-M, CuSi, CrNi, CuAl
Active / Passive
Synergic / Smart / Classic
Method / 2 / 4
MIG/MAG - MMA -
LIFT TIG
Crater
Burn Back
Crater
Burn Back
Burn Back
Burn Back
2- Position MIG
Factory Setting
0,1 sec
0,1 sec
0 step
0,2 sec
0,0 sec
1,0 mm
1,0 mm
Passive
2
MIG / MAG
Operation
Post Gas
Post Gas
Post Gas
Post Gas
Post Gas
4- Position MIG