Introduction
WARNING: Before you operate the product,
carefully read and understand the safety
chapter and the operation instructions.
Before use
WARNING: Connect the power plug to a
power outlet with the correct voltage, see
the type plate.
Grounding instructions
WARNING: The product must be grounded.
If it should malfunction or breakdown,
grounding provides a path of least
resistance for electric current to reduce the
risk of electric shock. The product is
equipped with a cord having an equipment-
grounding conductor and grounding plug.
The plug must be inserted into an
appropriate outlet that is properly installed
and grounded in accordance with all local
codes and ordinances.
Polarized plug
WARNING: To reduce the risk of electric
shock, this product has a polarized plug
(one blade is wider than the other). This plug
will fit in a polarized outlet only one way. If
the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact
a qualified electrician to install the proper
outlet. Do not change the plug in any way.
To connect the correct evacuation hose
The adapter fit most 25 mm/ 1 inch hoses.
•
Use the attached adapter.
•
Fit the adapter on the hose end.
•
Attach the adapter to the outlet.
To attach the suction hose
There is a hose intake with a hose lock on the product.
The hose lock makes sure that the suction hose adapter
do not fall off.
1. Lift the hose lock and attach the suction hose
adapter.
6
Operation
2. Lower the hose lock into the recess of the adapter.
To attach the nozzle on the hand pipe
The floor nozzle has adjustable wheels. Adjust the
wheels to get the best suction effect. Adjust the wheels
with the knob, which is on the rear side of the nozzle.
The wheels and rubber strips of the nozzle can be
replaced. Keep the nozzle in good condition.
To start and stop the W 70 P and the W
250 P
The motor switch is the button A and the pump switch is
the button B referring to the figure.
•
Push the button (1) to start the product.
•
Push the button (0) to stop the product.
MOTOR
0
1
A
After use
1. Switch off the suction apparatus with the switch.
2. Disconnect the power cord. Do not remove the pump
cable.
3. Empty and clean the suction apparatus and the
accessories used. Refer to
hose on page 6 and To clean the product on page
8 .
To change the bag
1. Disconnect the power cord and remove the pump
cable.
2. Loosen the 3 toggle fasteners and remove the top.
3. Lift out the float.
4. Remove and dispose the old bag. Refer to local
regulations.
5. Insert the new bag into the stainless steel strainer.
6. Thread the small opening over the internal inlet pipe.
Let the tab rest over the container rim.
7. Do step 1-3 in reversed order.
PUMP
MOTOR
0
0
1
1
B
A
To attach the suction
915 - 002 - 02.04.2019
PUMP
0
1
B