ELECTRIC DRYER ELECTRICAL CONNECTIONS
Connecting 3-Wire Connection: Power Supply Cord
Standard Power Cord Connectors
2. Connect neutral wire to center terminal block.
me
XS
Flanged spade connector
Ring Connector
Connecting Neutral Wire
1. Loosen or remove center terminal block screw.
| block screws.
Connecting 4-Wire Connection: Direct Wire
IMPORTANT: A 4-wire connection is required for mobile
Connecting Ground and Neutral Wires
homes and where local codes do not permit the use of 3-wire
1. Remove center terminal block screw and the ground wire
connections.
by removing the external ground connector screw.
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer can be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,
leaving bare ground wire at 5" (127 mm). Cut 172" (38 mm)
from 3 remaining wires. Strip insulation back 1" (25 mm).
Shape ends of wires into a hook shape.