I N T E R N A L B LO W E R
I C B D D 3 0 I , I C B D D 3 6 I A N D I C B D D 4 5 I
Mount a standard 220-240 V AC electrical
box, with 3-pronged grounded receptacle,
inside the cabinet or adjacent cabinet. Make
sure it is located within the reach of the
downdraft's 2.5 m power cord.
Run the appropriate power cable into the
cabinet and connect it to electrical box and
outlet.
Plug the power cord of the downdraft into
the outlet.
16
D O W N D R A F T
V E N T I L AT I O N S Y S T E M S
W I R I N G
R E M OT E B LO W E R
W I R I N G
I C B D D 3 0 R , I C B D D 3 6 R A N D I C B D D 4 5 R
Mount a standard 220-240 V AC electrical
box, with 3-pronged grounded receptacle,
inside the cabinet or adjacent cabinet. Make
sure it is located within the reach of the
downdraft's 2.5 m power cord.
Run the appropriate power cable into the
cabinet and connect it to electrical box and
outlet.
The remote blower may not exceed a 3.0
amp rating.
Run 2-wire plus ground power cable from
the remote blower to the electrical box on
the remote blower adapter plate.
Connect the downdraft wiring to the power
cable from the remote blower. Wire brown
to brown, blue to blue and green/yellow to
green/yellow. Refer to the illustration below.
Replace the electrical box cover.
Plug the power cord of the downdraft into
the outlet.
IMPORTANT NOTE: For mounting and
installation of the remote blower, refer to the
installation instructions for your specific
blower.
brown to brown
220-240 V AC
line in
blue to blue
Wiring connections
green/yellow to
green/yellow