m Electrical connection
The installed electric motor is completely wired ready for
operation.
The customer's connection to the power supply system, and
any extension cables that may be used, must conform with
local regulations.
Defective electrical connection cables
Electrical connection cables often suffer insulation dam-
age.
Possible causes are:
• Pinch points when connection cables are run through
window or door gaps.
• Kinks resulting from incorrect attachment or laying of
the connection cable.
• Cuts resulting from running over the connecting cable.
• Insulation damage resulting from forcefully pulling out
of the wall socket.
• Cracks through aging of insulation.
Such defective electrical connection cables must not be
used as the insulation damage makes them extremely
hazardous.
Check electrical connection cables regularly for dam-
age. Make sure the cable is disconnected from the mains
when checking.
Electrical connection cables must comply with the regu-
lations applicable in your country.
Single-phase motor
• The mains voltage must coincide with the voltage spec-
ified on the motor's rating plate.
• Extension cables up to a length of 25 m must have a
cross-section of 1.5 mm
2.5 mm
.
2
• The connection to the mains must be protected with a
16 A slow-acting fuse.
Only a qualified electrician is permitted to connect the
machine and complete repairs on its electrical equip-
ment.
In the event of enquiries please specify the following
data:
• Motor manufacturer
• Type of current of the motor
• Data recorded on the machine's rating plate
• Data recorded on the switch's rating plate
If a motor has to be returned, it must always be dis-
patched with the complete driving unit and switch.
, and beyond 25 m at least
2
Accessories
rAiL
m Maintenance
if specialist personnel must be brought in for extraordinary
ser vice or repairs during the warranty period and thereaf-
ter, please contact a service provider recommended by us or
con tact the manufacturer directly.
• Overhauls, maintenance work, cleaning, as well as the
eli mi nation of any malfunctions must only be under-
taken af ter turning off the motor.
• All protective and safety equipment must be rein-
stalled immediately upon completion of any repair or
maintenance work.
rEGULAr MAiNTENANCE
The regular maintenance decribed above and in the para-
graph below can be carried out by unskilled personnel.
• Do not oil the plunge cut saw, cause cutting must be
carried out in dry conditions; all rotating parts are
self-lubricating.
• During maintenance, wear protective gear if possible
(accident-prevention goggles and gloves).
• Remove cuttings when necessary both from the cutting
area, work surfaces and support bases.
Use of an aspirator or brush is recommended.
ATTENTioN: Do not use compressed air jets!
• Regularly check blade conditions: if difficulties should
arise during cutting, have it sharpened by skilled per-
sonnel or replace it if necessary.
ASSiSTENCE
When in need of skilled personnel for special main-
tenance, or for repairs, both during and following the
guarantee pe riod, always apply to authorized centres for
assistance or directly to the manufacturer if there is no
authorized centre in your area.
DiSPoSAL oF THE MACHiNE.
Once its operating activity is finished, the disposal of the
machine must take place through a normal collection and
disposal Center for industrial waste.