11.0 Diagnosis of faults and repair
Fault
The motor fails to start
Working pressure too high
Working pressure too low
Irregular working pressure
During self-priming
During direct water
connection
No working pressure
Should faults occur other than those mentioned above, please contact the nearest Nilfi sk-ALTO service
or gan i za tion.
All manuals and user guides at all-guides.com
Cause
Oil supply not connected
Oil supply closed
No oil pressure
The pump is frozen
Nozzle partly blocked
Valve for regulation of water
capacity is not adjusted to max. of water. Turn in the direction
pressure
Regulating valve open
Air in the pump
Suction height too high or water Read the paragraph 3.1 conc. self-
too hot
Filter blocked
Insuffi cient water supply from
the water works
Nozzle blocked
No water
High pressure hose/lance frozen Allow the high pressure hose/lance
By-pass valve frozen
Repair
Connect the oil hose.
Open the valve.
Start the hydraulic pump.
Let the pump thaw.
Clean the nozzle.
Open fully the valve for regulation
indicated by the arrow.
Close the regulating valve.
Repeat the venting procedure.
priming.
Clean the fi lter. See paragraph 7.3.
Change to a water supply with
greater output. If this is not
possible; turn the valve for regulation of
the water capacity in the opposite
direction of that indicated by the
arrow, until the machine works smooth ly.
Clean the nozzle.
Check the water connection.
to thaw.
Allow the machine to thaw.
EN