first 16 zone numbers on the DGP to which they are
connected.
DGP siren outputs (ATS1250/1260 only)
The ATS1250/1260 siren (speaker) output is available as the
last of the 16 output numbers associated with that DGP
address. For example, on DGP 3 the siren output is output 64.
See Table 8 below).
Table 8: Siren output numbers per DGP
DGP
Siren outputs
DGP 1
32
DGP 2
48
DGP 3
64
DGP 4
80
DGP 5
96
DGP 6
112
To enable the siren output, the output number representing the
siren output must be assigned to the required "Siren Event
Flag Number". The "Siren Event Flag Numbers" are
programmed in programming menu 2 - Area Databases, which
is described in the ATS control panel programming manual.
Outputs devices
ATS1810: Four-way relay card allows the use of output
numbers 5 to 8 of the outputs allocated to the DGP address.
For example, DGP 1 uses unlock relays 17 to 20 for opening
doors, and outputs 21 to 24 are available on the relay card.
Note:
This card cannot be used together with
ATS1811/ATS1820 clocked output cards.
ATS1811: Eight-way relay cards allow use of output numbers
5 to 48 of the outputs allocated to the DGP address. For
example, DGP 1 uses unlock relay 17 to 20 for opening doors,
and outputs 21 to 63 are available on the relay cards.
ATS1820: 16-way open collector card. It is the same as
ATS1811.
The four-door/four-lift DGP can activate outputs 33 to 63 only
by utilizing macro logic.
When using more than two ATS1811 or ATS1820, use
a separate power supply.
ATS125x/1260 default zone and relays settings
Table 9: Defaults
ATS125x
Door 1
Door contact
1
Request-to-Exit zone
2
DOTL
9
Door relay
K1
ATS1250
Door 1
Door contact
1
Request-to-Exit zone
3
DOTL
16
Door relay
K2
ATS1260
Lift 1
Starting floor
1
16 / 66
All manuals and user guides at all-guides.com
DGP
Siren outputs
DGP 7
128
DGP 8
144
DGP 9
160
DGP 10
176
DGP 11
192
DGP 12
208
Door 2
Door 3
Door 4
3
5
7
4
6
8
10
11
12
K2
K3
K4
Door 2
Door 3
Door 4
4
7
10
6
9
12
15
14
13
K3
K4
K5
Lift 2
Lift 3
Lift 4
1
1
1
Last floor
64
Starting relay
1
Starting zone
1
The zone numbers in Table 9 above refer to the physical zone
numbers on the ATS125x/1260 PCB.
The system zone numbers relating to these functions for each
of the ATS125x/1260 can be found in Table 6 on page 15.
Door and lift numbering
Door numbers are determined by:
•
The RAS or reader address when connected to the ATS
system databus (doors 1 to 16).
•
Four-door/four-lift DGP address (doors 17 to 64).
Doors 1 to 16 are reserved for RAS 1 to 16 and are connected
to the ATS system databus. These only provide basic access
control (door opening).
Doors 17 to 64 are used for door numbers and are controlled
by a four-door/four-lift DGP (ATS125x/1260). These doors
provide enhanced access control functions (anti-passback,
etc).
Table 10: Door and lift numbers allocated per DGP
Device address
Door or lift number
RAS 1 to 16
1 to 16 (door open only)
1
DGP 1
17
DGP 2
21
DGP 3
25
DGP 4
29
DGP 5
33
DGP 6
37
DGP 7
41
DGP 8
45
DGP 9
49
DGP 10
53
DGP 11
57
DGP 12
61
Power-up procedure
When the installation is complete, ensure that the unit is
addressed correctly using DIP switches 1 to 4 (1 to 12 are
available).
Check if the RAM memory in the ATS125x/1260 and the
Advisor Master control panel is the same.
On initial power-up, the LEDs on the four-door/four-lift DGP
should indicate as follows:
•
RST (ATS125x) / OK (ATS1250/1260): Off
ATS system databus indicator LEDs:
•
Rx1 (ATS125x) / Rx0 (ATS1250/1260): Flashes if
ATS125x/1260 receives polling from the ATS control
panel.
P/N 1070341 (ML) • REV F • ISS 16APR18
64
64
64
65
129
193
65
129
193
2
3
4
18
19
20
22
23
24
26
27
28
30
31
32
34
35
36
38
39
40
42
43
44
46
47
48
50
51
52
54
55
56
58
59
60
62
63
64