The clock can be displayed in a twelve hour format and
valid clock times are from 1:00 to 12:59.
•
The clock can be reprogrammed pressing the "Timer"
key for 5 seconds, and after, the clock can be adjusted
with the "+" and "-" keys. Colon ":" will flash indicating
clock programming mode.
•
The user can have minute increments / decrements of 1
minute, but if the user keep pressing the "+"/"-" keys
for more than 1 second, the increments / decrements will
be of 5 minutes. During this option the control will
round to the nearest 5 minutes.
•
The user can finish on reprogramming the clock pressing
the "timer" key.
•
After 1 minute of no key pressed the control will accept
the programmed clock time and will add one minute
to the set clock.
Grease filter saturation alarm
•
After thirty fan functional hours, the display will show
"Grease Filter" if the fan is active. When this icon is
shown in the display, the grease filters installed are
required to be washed.
•
To reset the grease filter saturation alarm the user must
press the "+" key for 5 seconds, after this action the
icon "grease filter" is not display, and the hood has the
normal display operation.
Charcoal filter saturation alarm (Recirculating accessories)
•
After one hundred and twenty functional hours of the fan,
the display will show "Charcoal Filter" if the fan is active.
When this icon flashes on display, the charcoal filters
installed are required to be replaced or reactivated.
•
To reset the grease filter saturation indication the user
must press the "-" key for 5 seconds, after this time
the icon "charcoal filter" is not display and the hood has
the normal display operation.
Audible signal activation and deactivation
•
The audible signals can be activated or deactivated
pressing the "Light" key for 5 seconds.
•
If the audible signal is activated, a tone must sound and
the "Snd" symbol must appear on the display for 2 second.
•
If the audible signal is deactivated, the "Snd" symbol must
appear on the display for 2 second and no sound must sound.
Charcoal filter inclusion and exclusion
(Recirculating accessories)
•
The charcoal filter inclusion or exclusion can be set by
pressing the "-" and "+" keys at the same time for 5 seconds.
•
The Inclusion or exclusion of charcoal filter must be
selected while the lamps and the motor are OFF.
•
When the charcoal has been excluded, the charcoal filter
alarm is disabled.
Heat sensor
•
The control is equipped with a heat sensor that will turn
on the blower at second speed if excessive heat
occurs (over 70°C) surrounding the control area.
•
If the blower is OFF or if it is operating at first speed, the
blower will be set automatically to second speed.
•
During this state, the user may raise the blower speed to
third speed but can not decrease the speed.
•
When the temperature level on the hood drops to normal,
the blower will operate in the setting defined by the user
before the alarm occured.
Metal grease filter maintenance
The metal filter traps grease released by foods on the cook-
top. The filter must always be installed when the hood is
operating / used.
To remove:
•
Push the filter lock / pivot in direction to the center of the
filter.
•
Once the pivot is pushed pull down the filter slowly.
To replace:
•
Insert the filter tabs into the slots
•
Push the filter lock / pivot in direction to the center of the
filter.
•
Once the pivot is pushed, raise the filter slowly until the
top and release the pivot.
To clean:
•
Swish the filter in hot soapy water and rinse in clean
water or wash it in the dish washer.
•
Do not use abrasive cleaners.
Hood maintenance
•
Clean with a damp, soapy cloth and dry with a clean cloth.
A glass cleaner may also be used.
ATTENTION: Do not wet the control panel.
•
Do not use a steel wool pad; it will scratch the surface.
•
To clean the stainless steel surface, use warm sudsy
water, stainless steel cleaner or polish. Always wipe
the surface in the direction of the grain. Follow the cleaner
instructions for cleaning the stainless steel surface.
11