Inspection / Maintenance - REMS Solar-Push I 80 Notice D'utilisation

Masquer les pouces Voir aussi pour Solar-Push I 80:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
eng
CAUTION
CAUTION
Danger of scalding at high transported medium temperature. Fill the system
only when it is in its cold state; cover the solar collectors if necessary.
First unscrew the pressure and return lines on the fi lling and fl ushing unit, connect
the open hose ends with a connecting piece, e.g. ¾" double nipple in order to
prevent transported medium from dripping of running out during transport.
NOTICE
NOTICE
Avoid environmental damage from outfl owing transported media. Collect
outfl owing transported medium immediately and dispose of it in accordance
with the national regulations that apply.
To fl ush heavily contaminated systems, e. g. underfl oor heating and to clear
slurries, use a fi ne fi lter unit with a large dirt collection vessel (accessory)
(page 2.4.) or a screw lid with return connection ¾" and fi ne fi lter bag 70 μm
(accessory) (see 2.3.).
NOTICE
NOTICE
Danger of frost: If the pump is exposed to temperatures ≤ 5°C, the pump body,
the plastic tank and the hoses must be completely emptied to avoid damage.
This procedure is also recommended at normal temperatures when the pump
is not used for long periods of time.
4. Maintenance
Notwithstanding the maintenance described below, it is recommended to send
in the electrical fi lling and fl ushing unit to an authorised REMS contract customer
service workshop for inspection and periodic testing of electrical devices at
least once a year. In Germany, such periodic testing of electrical devices should
be performed in accordance with DIN VDE 0701-0702 and also prescribed for
mobile electrical equipment according to the accident prevention rules DGUV,
regulation 3 "Electrical Systems and Equipment". In addition, the respective
national safety provisions, rules and regulations valid for the application site
must be considered and observed.
5. Faults
WARNING
WARNING
Switch off the On/Off switch and pull out the mains plug before repairing the fault on the electrical fi lling and fl ushing unit.
5.1. Fault: Pump does not suck up or is not working.
Cause:
● Unsuitable transport medium.
● Leaking suction pipe.
● Suction pipe or fi ne fi lter blocked.
● Pressure hose is blocked.
● Ball valve (4) is closed.
● The plastic tank (3) is empty.
● Air in the pump (Solar-Push K 60).
● Pump has seized (Solar-Push K 60).
● Power cable defective.
● Pump/motor defective.
5.2. Fault: Pump builds up no pressure or does not transport the medium.
Cause:
● Transport height exceeded.
● Unsuitable transport medium.
● Ball valves/solar unit connecting valve not opened/closed correctly.
● Fine fi lter blocked.
● Pump/motor defective.
5.3. Fault: Liquid escapes from the pump.
Cause:
● Seals of the pump connections are defective.
● Pump seals are defective.
4.1. Maintenance
WARNING
WARNING
Pull out the mains plug before maintenance work!
Clean the pump regularly in order to prevent the pump parts from sticking,
particularly if they are not used for a n extended period. Store the pump in a
frost-proof location. Check hoses, hose connectors and seals for damage before
every use. Do no used damaged hoses and seals.
Check the fi ne fi lter of the pump for contamination regularly through the sight
glass (7) and clean if necessary. To do this, unscrew the sight glass (7) on the
fi le fi lter, remove the fi lter screen and clean both under running water or with
compressed air. Replace damaged fi lters.
Clean plastic parts (e.g. housing) only with REMS CleanM machine cleaner
(Art. No. 140119) or a mild soap and a damp cloth. Do not use household
cleaners. These often contain chemicals which can damage the plastic parts.
Never use petrol, turpentine, thinner or similar products for cleaning.
Make sure that liquids never get onto or inside the pump motor.

4.2. Inspection / maintenance

WARNING
WARNING
Pull out the mains plug before carrying out maintenance or repair work!
This work may only be performed by qualifi ed personnel.
Remedy:
● Only use approved transport media (see 1. Intended Use and 1.3.).
● Change seal/suction pipe.
● Clear the blockage in the suction pipe. Clean fi le fi lter7fi lter screen (see 4.1.)
or change fi lter screen.
● Clear the blockage in the pressure hose.
● Open ball valve.
● Fill or refi ll the plastic tank with transport medium (see 3. Operation).
● Fill liquid into pump (see 3. Operation).
● Push a fl at screwdriver through the middle hole in the motor fan cover and
release the blockage by turning abruptly to the left and right several times.
● Have the power cable changed by qualifi ed personnel or an authorised REMS
customer service workshop.
● Have the pump/motor checked/repaired by an authorised REMS customer
service workshop.
Remedy:
● Check transport height (see 1.3.).
● Only use approved transport media (see 1. Intended Use and 1.3.).
● Open/closed ball valves according to 2.2.
● Clean the fi ne fi lter/fi lter screen (see 4.1.) or change the fi lter screen.
● Have the pump/motor checked/repaired by an authorised REMS customer
service workshop.
Remedy:
● Change seals.
● Have the pump checked/repaired by an authorised REMS customer service
workshop.
eng
9

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Solar-push k 60

Table des Matières