INSTALLATION STEP 6
Install the Control Console
Locate control console within sight of door, at a minimum
height of 5 feet (1.5 m) where small children cannot
reach, away from moving parts of door and door
hardware. If installing into drywall, drill 5/32" holes
(Figure 1) and use the anchors provided. For pre-wired
installations (as in new home construction), it may be
mounted to a single gang box (Figure 2).
1. Strip 7/16" (11 mm) of insulation from one end of bell
wire and connect to the two screw terminals on back of
control console by color: white wire to 2 and white/red
wire to the 1.
2. Remove cover by gently prying at slot in top of the
cover with a small flat head screwdriver. Fasten with
6ABx1-1/4" self-tapping screws (drywall installation) or
6-32x1" machine screws (into gang box) as follows:
• Install bottom screw, allowing 1/8" (3 mm) to protrude
above wall surface.
• Position bottom of control console on screw head
and slide down to secure. Adjust screw for snug fit.
• Drill and install top screw with care to avoid cracking
plastic housing. Do not overtighten.
• Insert top tabs and snap on cover.
3. (For standard installation only) Run bell wire up wall
and across ceiling to motor unit. Use insulated staples
to secure wire in several places. Do not pierce wire
with a staple, creating a short or open circuit.
4. Strip 7/16" (11 mm) of insulation from end of bell wire.
Connect bell wire to the quick-connect terminals as
follows: white to white and white/red to red.
5. Position the antenna wire as shown.
6. Use tacks or staples to permanently attach entrapment
warning label to wall near control console, and manual
release/safety reverse test label in a prominent
location on inside of garage door.
NOTE: DO NOT connect power and operate opener at
this time. The trolley will travel to the full open position
but will not return to the close position until the sensor
beam is connected and properly aligned.
Top
Mounting
Hole
WHITE
Terminal
2
Screws
RED
Bell
Bottom
1
Wire
Mounting
Hole
(BACK VIEW)
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Disconnect ALL electric and battery power BEFORE
performing ANY service or maintenance.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install control console within sight of garage door, out of
reach of children at a minimum height of 5 feet (1.5 m), and
away from ALL moving parts of door.
• NEVER permit children to operate or play with control
console push buttons or remote controls.
• Activate door ONLY when it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
Outside Keylock Accessory Connections
To opener quick-connect terminals: white to white;
white/red to red.
Screw 6-32x1"
(pre-wired)
Figure 1
STANDARD WALL MOUNT
To Replace
Insert Top
Tabs First
Push Bar Cover
Control Console Connections
Strip wire 7/16" (11 mm)
7/16" (11 mm)
Red
17
WARNING
WARNING
HARDWARE SHOWN ACTUAL SIZE
Screw 6ABx1-1/4"
(standard installation)
PRE-WIRED INSTALLATION
To Replace
Insert Top
Tabs First
ON
OFF
Detector
Switch
Push Bar Cover
To release wire, push in
tab with screwdriver tip
White
Grey
Insulated
Staples
Drywall Anchors
Figure 2
24 Volt Bell Wire
Detector
ON
Switch
OFF

Publicité