2.9
Only for sectional and spring operated garage doors
Fasten the draw slide I on the upper portion of the door
maintaining the previously marked reference points.
Connect the perforated bar L and the curved arm M using
2, 6 x 15 bolts. Connect the curved arm M and the draw
plate I using the cylindrical headed pivot with the provided
split pin.
3.
Only for counter-weighted garage doors
Fasten the arch arm 162504 on the upper portion of the
door maintaining the previously marked reference points.
The two anchor plates (upper and lower) of the arch
162504 must be in the same plane. If not, add shims.
Connect the perforated bar L to the perforated bar of the
arch arm using 2, 6 x 15 bolts.
All manuals and user guides at all-guides.com
18
RELEASE OF THE AUTOMATION
In order to release the automation from inside, pull the knob
downwards.
m
CAUTION: Do not use the knob to open the door.
It is prohibited to hand objects off the release cord.
In order to release the automation from outside, install the
accessory release kit (code 162518).
m
WARNING: If the door is unlocked to be opened, when
it will be closed it is automatically locked for security
reasons.
If the power supply is not available, the door can be opened
only by acting again on the release knob.
If there are no secondary accesses to the garage we
recommend the installation of the device to unlock from the
outside (code 162518)