Télécharger Imprimer la page

ADURO 1.1 Serie Mode D'emploi page 32

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57
2.1 Position of the stove / distance requirements
Distance requirements will only apply if the wood burning stove is to be placed close to flammable materials:
Distance to flammable
material (cm)
Aduro 1.1
Aduro 1.1SK
Aduro 1.4
Aduro 9
Aduro 9.1
Aduro 9.3
Aduro 9.4
Aduro 9.5
Aduro 9.6
Aduro 9.7
A
If the stove is positioned against a brick wall or other non-flammable material, there are no minimum distance
requirements. To facilitate cleaning and for the best use of the convection air, we recommend that you keep
a distance of approximately 5-10 cm to the wall.
If the wood burning stove is to be placed on a flammable material (or above flammable material for Aduro
9.4) such as a wooden floor or carpet, it must be placed on a non-flammable floor hearth. The floor hearth
should extend for at least 30 cm in front of the stove and 15 cm on each side measured from the opening of
the combustion chamber.
The wood burning stove must be installed on a floor with the adequate load-
bearing capacity. If the existing construction does not meet this requirement,
appropriate adaptation measures must be taken (e.g. a load-distributing plate).
2.2 Pipe connection
Please ensure that all local rules and regulations are complied with, including CE marking of the flue pipe.
Additionally, distance requirements to flammable material for the pipe must be respected.
A flue pipe with an internal diameter of 150 mm should be used for all Aduro stoves.
To the sides
Behind the stove
(A)
(B)
40
7.5
40
7.5
40
7.5
70
20
40
7.5
70
7.5
70
7.5
70
7.5
70
20
70
7.5
B
C
C
Distance to
Corner position
furniture (C)
100
100
100
80
100
100
100
100
80
100
D
D
Above the
(D)
stove
10
50
10
50
10
50
-
50
10
50
-
50
-
50
-
50
-
50
-
50
C
32

Publicité

loading

Ce manuel est également adapté pour:

9 serie1.11.1sk1.499.1 ... Afficher tout