Installation
15
Access Panel
Make all connections before installing access panel.
If access panel brackets were
previously installed in Step 1,
skip A and proceed to B.
Install access panel brackets
to wall using #10 fasteners
(supplied by installer) as
A
shown in rough in drawing.
Install top screw into slot. Do
not install bottom screw until
Step C is complete.
Insert #10 thumbscrews
into front bowl apron as
B
shown. Thumbscrew in
vertical position is closed.
Thumbscrew in horizontal
position is open.
Hang access panel onto
mounting brackets attached
to wall on the left and right
sides. Rotate panel up
and check fitup between
C
thumbscrews and panel slots.
Rotate access panel down
and make adjustment to
brackets if necessary. Install
bottom #10 fastener into
brackets.
D
Attach P-trap to drain adapter
and waste outlet.
Plug the grounding wire
E
assembly adapter from
WashBar to wall outlet.
Plug dryer power cord
from dryer motor into
GFCI protected wall outlet.
F
WashBar LEDs will light up
blue. Wait 5 seconds. Place
hands under soap dispenser,
water and dryer to be sure
all 3 functions work properly.
Check for water leaks.
Bradley • 215-1843 Rev. E; ECN 18-08-023
#10
Thumb
Screw
#10 Top
Screw
Information
Label
Rotate access panel up
G
and secure by rotating
thumbscrews to the closed
position.
To open access panel, rotate
thumb screw, slightly push
H
panel up and swing access
panel down. Do not remove
thumbscrews.
CAUTION For applications where
Shown in closed
position. Rotate
90° to Open
2/4/2019
LVQD2
children are present or
for applications subject
to vandalism, order
security screw option
S45-2880.