Installation
NOTE!
Before commissioning, make sure that the unused supply connectors (PWR1, PWR2) are
covered with blind plugs (see Error! Reference source not found.) / label [Error!
Reference source not found.]).
Figure 2)
Connection Diagram
F1
= 3,15 A
OCP
= Over Current Protection
Sensor connection
NOTE!
The assembly may be carried out only in a voltage-free state (no measuring mode).
1. Place the shield of the sensor cable either on the shield terminal of the device (see Error!
Reference source not found.), label [6)]) or on an external shield terminal.
NOTE!
Ensure correct polarity of the sensor lines. Polarity reversal can cause damage to the
sensor.
2. Connect the SIG and COM wires of the sensor cable to the SIG and COM of the socket CH1-4.
Page 10 of 18
© Brüel & Kjaer Vibro ● C106330.001 / V02 ●
Technical alterations reserved!