Télécharger Imprimer la page

EQUATION AM-H09B5A4/MIR2-B6 Mentions Légales & Consignes De Sécurité page 107

Climatiseur local

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
or compressor oils are to be removed, ensure that they have been evacuated to an
acceptable level to make certain that flammable refrigerant does not remain within
the lubricant. The evacuation process shall be carried out prior to returning the
compressor to the suppliers. Only electric heating to the compressor body shall be
employed to accelerate this process. When oil is drained from a system, it shall be
carried out safely.
19. Transport of equipment containing flammable refrigerants (Annex CC.1)
Compliance with the transport regulations
20.Discarded appliances supplies flammable refrigerants
See National Regulations.
21.Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer's
instructions.
22.Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage to
the equipment inside the package will not cause a leak of the refrigerant charge. The
maximum number of pieces of equipment permitted to be stored together will be
determined by local regulations.
23.Marking of equipment using signs
See local regulations