FILLING THE FUEL TANK.
Fill the tank with fuel for Diesel
motors (fig. 1).
If the boiler does not start up
after filling with fuel, leave the
appliance in operation for a
few seconds with the water
gun off (by-pass phase) and
burner switch on (fig. 6B).
!
Do not use different fuel from that indicated on the
identification plate. Check the fuel level from time to time
while the cleaner is operating.
Attempting to use the cleaner without fuel may cause
damage to the fuel pump.
When the tank is empty, the diesel pump is excessively
noisy.
FILLING THE DETERGENT
TANK.
From the range of recommen-
ded products, choose the one
most suited to the washing job
to be done (fig. 2) and dilute
it with water according to the
instructions on the pack.
Fill the detergent tank with the
diluted product (fig. 3).
Ask your dealer for the cata-
logue of the detergents that
can be used depending on
the type of washing job to be
done and the type of surface
to be treated.
After using a detergent, the
detergent intake circuit must
be flushed out with clean
water.
COMMAND AND CONTROL DEVICES
!
Before connecting the machine to the water supply and
to the power mains, it is essential to know the function of the
cleaner's command and control devices.
English
WATER CIRCUIT CONNEC-
TION.
Connect the feed hose to
the mains (fig. 4A) and to
the hosetail on the cleaner
(fig. 4B).
Check that the pressure and
quantity of the water supplied
by the mains are sufficient for
the cleaner to work properly: 2
to 8 BAR (29 to 116 PSI).
Maximum temperature of fee-
ding water 50°C (122°F).
FIG. 1
Connect the high pressure
hose to the cleaner (fig. 4C)
and to the lance (fig. 5).
IMPORTANT.
The cleaner must operate
with clean water. Dirty or
sandy water, corrosive che-
micals and solvents can
cause severe damage to
the cleaner.
Failure to respect the above
absolves the manufacturer
of all liability and repre-
sents negligent use of the
product.
ELECTRICAL CONNECTION.
Connection of the cleaner to the mains must be carried out
be skilled technicians able to ensure that all regulations in
FIG. 2
force are complied with
and legislation.
Ensure that the mains voltage available is the same as the vol-
tage at which the cleaner is supposed to work; this is indicated
on the identification plate.
The electric cable must be protected from accidental cru-
!
shing.
!
Do not use the machine if the supply cable is damaged.
!
The use of any electric appliance requires the respect of
some basic rules:
• Do not touch the appliance with wet or damp hands or feet.
• Do not use the appliance bare-footed or with unsuitable
clothing.
FIG. 3
• Do not pull the supply cable or the appliance itself in order
to disconnect the plug from the electric supply.
(For water cleaners rated at less than 3 kW fitted with
As for the protection against electric shock, the H.P.cleaner
belongs to CLASS I.
!
Failure to observe the above warning frees the manu-
facturer from all responsibility and constitutes negligent
use of the product.
- 18 -
use in respect of current standards
FIG. 4
FIG. 5
plug).