Fault causes
Fault
Fan does not start
Fan does not turn
(no longer turns)
Fuse has tripped
Vibrations
Abnormal noises
Fan no longer perfor-
ming (speed)
8�3
Standstill and disposal
m
DANGER
When dismantling, live parts can be exposed, which can result in electric shock if touched� Before dismant-
ling, isolate the unit from the mains power supply and protect against being switching on again!
Parts and components of the fan, whose service life has expired, e.g. due to wear and tear, corrosion, mechanical load,
fatigue and/or other effects that cannot be directly discerned, must be disposed of expertly and properly after disassem-
bly in accordance with the national and international laws and regulations. The same also applies to auxiliary materials
in use. Such as oils and greases or other substances. The intended and unintended further use of worn parts, e.g.
impellers, rolling bearings, filters, etc. can result in danger to persons, the environment as well as machines and
systems. The corresponding operator guidelines applicable on-site must be observed and used.
Causes
– No voltage
– Impeller blocked
– Motor blocked
– Mains voltage failure
– Temp. monitoring system has
triggered
– Fuse has tripped
– Impeller is blocked or
contaminated
– Shorted coil in motor
– Supply line or connection
damaged
– Connected incorrectly
– Contamination
– Attachment-related resonance
– Grinding impeller
– Bearing damage
– Mechanical damage
– Insufficient air delivery
– Incorrect voltage
– Bearing damage
– Contamination
– Insufficient backflow
14
Solution
Check mains voltage
Check connection according to wiring diagram
Clear blockage, clean, replace if necessary
Contact Helios customer services
Check mains voltage
- Check/clear inflow and outflow
- Check transport media, ambient temperature
- Check mains voltage
«Fuse has tripped»
Clear blockage, clean, replace if necessary
Contact Helios customer services
Replace parts, replace motor if necessary
(Contact Helios customer services)
Check, modify connection
Clean
Check or repair attachment
Clean impeller, replace if necessary
Contact Helios customer services
Carry out maintenance
Check/clear inflow and outflow
Check/modify connection
Contact Helios customer services
Clean
Widen backflow openings