Before you store the air compressor,
make sure you do the following:
1.
Review the "Maintenance"
section on the preceding
pages and perform scheduled
maintenance as necessary.
2.
Set the On/Auto/Off lever to
"OFF".
3.
Turn the regulator
counterclockwise and set the
outlet pressure to zero.
4.
Remove the air tool or accessory.
5.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
6.
Drain water from air tank by
opening drain valve on bottom of
tank.
A14123
All manuals and user guides at all-guides.com
STORAGE
air tank. If not drained, water will
corrode and weaken the air tank
causing a risk of air tank rupture.
7.
NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, then
reinstalled.
8.
Store the air compressor in a clean
and dry location.
20- ENG
Water will
condense in the
After the water has been drained,
close the drain or drain valve.
Protect the electrical cord and
air hose from damage (such as
being stepped on or run over).
Wind them loosely around
the compressor handle. (If so
equipped)

Publicité