Page 1
Owner’s Manual Permanently Lubricated Tank Mounted AIR COMPRESSOR Model No. 919.724572 • Safety Guidelines • Assembly • Operation • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating.
If this air compressor is used for commercial or rental purposes, the warranty will apply for ninety days (90) from the date of purchase. This Craftsman Air Compressor warranty gives you specific legal rights and you may have other rights which vary from province to province.
SPECIFICATION CHART Model No. 919-152142 Max. Developed HP Bore 47.625 Stroke 31.75 Voltage-Single Phase 120V Minimum Branch Circuit Requirement 10 amps Fuse Type Time Delay Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand.
Page 4
IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It Always operate the compressor in a well...
Page 5
HAZARD WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It Drain tank daily or after each use.
Page 6
HAZARD WARNING: Risk of Electrical Shock WHAT CAN HAPPEN HOW TO PREVENT IT Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used properly Never operate compressor with it may cause electric shock.
Page 7
HAZARD WARNING: Risk of Burns WHAT CAN HAPPEN HOW TO PREVENT IT Touching exposed metal such as the Never touch any exposed metal parts on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns.
Page 8
HAZARD Risk Unsafe Operation WARNING: WHAT CAN HAPPEN HOW TO PREVENT IT Unsafe operation of your air compressor Review and understand all instructions and warnings in this manual. could lead to serious injury or death to Become familiar with the operation and you or others.
GLOSSARY Become familiar with these terms When the tank pressure drops to a before operating the unit. certain low level the motor will restart automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
INSTALLATION IMPORTANT: The outlet being used HOW TO SET UP YOUR must be installed and grounded in UNIT accordance with all local codes and ordinances. Location of the Air Compressor Make sure the outlet being used Locate the air compressor in a clean, has the same configuration as dry and well ventilated area.
Extension Cords Voltage and Circuit Protection Using extension cords is not Refer to the Specification Chart for recommended. The use of extension the voltage and minimum branch cords will cause voltage to drop circuit requirements. resulting in power loss to the motor Certain air compressors can be and overheating.
OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Outlet Pressure Gauge On/Auto/Off...
Air Compressor Pump (not shown): Compresses air into the air tank. Quick Working air is not available until the Connect compressor has raised the air tank pressure above that required at the air outlet. On/Auto/ Check Valve: When the air Off Lever compressor is operating, the check valve is "open”, allowing compressed...
Before Each Start-Up: How to Start: Place On/Auto/Off lever to Turn the On/Auto/Off lever to "OFF" and close air regulator. "AUTO" and allow tank pressure to build. Motor will stop when Pull regulator knob out, turn tank pressure reaches "cut-out" counterclockwise until it stops.
MAINTENANCE Customer Responsibilities Daily or Before after each each Check Safety Valve Drain Tank To Drain Tank Unit cycles automatically when Set the On/Auto/Off lever to power is on. When performing "OFF". maintenance, you may be exposed Pull the regulator knob out and to voltage sources, compressed air, or moving parts.
SERVICE AND ADJUSTMENTS Remove the hose by removing Unit cycles the hose clamp. automatically when power is on. When doing NOTE: The hose clamp is not Maintenance, you may be exposed reusable. You must purchase a new to voltage sources, compressed air hose clamp, see the Parts List or moving parts.
Page 17
Assemble the regulator and To Replace Regulator orient as shown. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section. Unplug unit. Regulator Using an adjustable wrench remove the outlet pressure gauge and quick connect from the regulator.
STORAGE Before you store the air compressor, Water will make sure you do the following: condense in the air tank. If not drained, water will Review the "Maintenance" corrode and weaken the air tank section on the preceding pages causing a risk of air tank rupture. and perform scheduled maintenance as necessary.
Page 19
TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM CAUSE CORRECTION...
Page 20
PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated pressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the used.
Page 21
PROBLEM CAUSE CORRECTION Regulator will Damaged regulator. Replace. not shut off air outlet. Motor will not Motor overload protection Let motor cool off and run. overload switch will switch has tripped. automatically reset. Tank pressure exceeds Motor will start automatically when tank pressure drops pressure switch "cut-in"...
à compter de la date d’achat, sur un compresseur qui est utilisé à des fins commerciales ou comme appareil de location Cette garantie sur le compresseur d'air de Craftsman vous donne des droits particuliers. Il se peut que vous ayez d’autres droits qui varient d’une province à l’autre.
TABLEAU DES SPÉCIFICATIONS Modèle no : 919-152142 CV maximum développés Alésage 1 7/8 po (4,76 cm) Course du cylindre 1 1/4 po (3,175 cm) Tension – phase unique Exigence minimale du circuit de dérivation 10 a Genre de fusible à retardement à élément double Capacité...
DANGER RISQUE DE CHOC ÉLECTRIQUE RISQUE PRÉVENTION NE JAMAIS FAIRE FONCTIONNER LE VOTRE COMPRESSEUR D’AIR EST COMPRESSEUR À L’EXTÉRIEUR LORSQU’IL ALIMENTÉ PAR ÉLECTRICITÉ. COMME PLEUT OU DANS DES CONDITIONS HUMIDES. AVEC TOUS LES APPAREILS ÉLECTRIQUES, SI L’APPAREIL N’EST PAS UTILISÉ DE NE JAMAIS FAIRE FONCTIONNER LE FAÇON APPROPRIÉE, IL PEUT CAUSER DES COMPRESSEUR SANS LES COUVERCLES...
Page 25
DANGER RISQUE DE BRÛLURES PRÉVENTION RISQUE LE FAIT DE TOUCHER AUX SURFACES DE NE JAMAIS TOUCHER AUX PIÈCES DE MÉTAL EXPOSÉES TELLES QUE LA TÊTE DU MÉTAL EXPOSÉES DU COMPRESSEUR DURANT OU IMMÉDIATEMENT APRÈS LE COMPRESSEUR OU LES TUBES DE SORTIE FONCTIONNEMENT.
DANGER RISQUE DE DOMMAGES À LA PROPRIÉTÉ PENDANT LE TRANSPORT DU COMPRESSEUR (incendie, inhalation, dommages aux surfaces du véhicule) RISQUE PRÉVENTION DES FUITES OU DES DÉVERSEMENTS TOUJOURS PLACER LE COMPRESSEUR SUR D’HUILE PEUVENT SE PRODUIRE ET UN TAPIS DE PROTECTION POUR ÉVITER ENTRAÎNER DES RISQUES D’INCENDIE, OU L’ENDOMMAGEMENT DU VÉHICULE PAR DES DES PROBLÈMES AUX VOIES RESPIRATOIRES,...
LEXIQUE Veuillez vous familiariser avec ces termes avant La basse pression à laquelle le moteur se d'utiliser l'appareil. remet automatiquement en marche s'appelle la "pression d'amorçage". CFM : pieds cubes par minute (pi /min). Pression de rupture : Lorsqu'on met un SCFM : pieds cubes par minute (pi /min) compresseur d'air en marche et qu'il...
Page 28
INSTALACIÓN CÓMO PREPARAR LA UNIDAD Asegúrese de que el tomacorriente que será utilizado tenga la misma configuración que el enchufe de Ubicación del compresor de aire conexión a tierra. NO UTILICE UN Ubique al compresor de aire en una zona ADAPTADOR.
Page 29
Protection contre la surtension et Rallonges protection du circuit Utilisez un boyau d'air supplémentaire au lieu d'une rallonge pour éviter une chute de Consulter le Guide des pièces pour tension, une perte de puissance et la connaître les exigences minimums surchauffe du moteur.
UTILISATION Familiarisez-vous avec votre compresseur d'air LISEZ CE GUIDE DE L'UTILISATEUR ET TOUTES LES MESURES DE SÉCURITÉ AVANT D'UTILISER CET APPAREIL. Comparez les illustrations à votre appareil pour vous familiariser avec l'emplacement des commandes et boutons de réglage. Conservez ce guide pour références ultérieures.
Page 31
Pompe du compresseur d'air (non raccord à illustrée) : connexion La pompe comprime l'air pour le forcer rapide dans le réservoir d'air. L'air n'est pas disponible pour travailler avant que le compresseur n'ait élevé la pression du réservoir d'air au niveau requis à la sortie d'air.
Page 32
Avant chaque mise en marche : Mise en marche : Placez le levier "On/Auto/Off" à la Placez le levier "On/Auto/Off" à la position "OFF". position "AUTO" et attendez jusqu'à ce que la pression augmente. Tirez le bouton du régulateur et Le moteur s'arrêtera lorsque la tournez-le dans le sens contraire des pression dans le réservoir atteint la...
ENTRETIEN Responsabilités du client À chaque Avant jour ou chaque après utilisation chaque utilisation Vérifier la soupape de sûreté Vidanger le réservoir L'appareil Vidange du réservoir fonctionne Réglez le levier automatiquement en cycles lorsqu'il est marche/automatique/arrêt sous tension. En effectuant l'entretien, "On/Auto/Off"...
ENTRETIEN ET RÉGLAGES REMARQUE : Le collier du boyau ne peut pas compresseur être réutilisé. Il faut se procurer un collier de d'air fonctionne automatiquement lorsqu'il boyau neuf. Voir la Liste des pièces ou achetez est sous tension. En effectuant un collier de boyau standard d'une quincaillerie l'entretien, vous pourriez être exposé...
Page 35
Assemblez le régulateur et orientez-le Remplacement du régulateur tel qu'illustré. Déchargez tout l'air pressurisé du réservoir d'air. Voir la partie intitulée "Vidange du réservoir" de la section sur l'entretien. Régulateur Débranchez le compresseur d'air. À l'aide d'une clé réglable, retirez du régulateur le manomètre de sortie et le raccord à...
RANGEMENT L'eau dans le Avant de ranger le compresseur d'air, réservoir effectuez les étapes d'air peut condenser. Si le réservoir suivantes : n'est pas vidangé, l'eau corrodera et Revoyez la section intitulée affaiblira les parois du réservoir d'air, "Entretien" des pages précédentes et causant ainsi un risque d'éclatement du exécutez l'entretien requis.
DÉPANNAGE En effectuant des réparations au compresseur, il se peut que vous soyez exposé aux sources de tension, aux pièces mobiles ou aux sources d'air comprimé qui risquent de causer des blessures corporelles. Débranchez le compresseur et purgez l'air pressurisé du réservoir avant d'entamer toute réparation.
Page 38
PROBLÈME CAUSE CORRECTION Le relevé de pression Une légère chute de pression est S'il y a une chute excessive de sur le manomètre du considérée normale. pression lorsqu'un accessoire est régulateur tombe utilisé, ajustez le régulateur en lorsqu'un accessoire suivant les directives du paragraphe est utilisé.
Page 39
PROBLÈME CAUSE CORRECTION Fusible sauté ou coupe-circuit Vérifiez s'il y a un fusible sauté dans la Le moteur ne tourne boîte à fusibles et remplacez-le au déclenché. pas. besoin. Rétablissez le coupe-circuit. Ne pas utiliser un fusible ou un coupe- circuit à...
Page 40
Get it fixed, at your home or ours! Just Call: ® 1-800-4-MY-HOME (1-800-469-4663) 24 hours a day, 7 days a week For the repair of major brand appliances in your own home … no matter who made it, no matter who sold it! For your nearest Sears Parts and Service location, to bring in products like vacuums, lawn equipment and electronics.