Télécharger Imprimer la page

Craftsman 919.725502 Mode D'emploi page 17

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
6.
After the water has been drained,
close the drain valve (clockwise).
The air compressor can now be
stored.
NOTE: If drain valve is plugged, release
all air pressure. The valve can then be
removed, cleaned, the reinstalled.
Air Filter - Inspection and
Replacement
Hot surfaces.
Risk of burn.
Compressor heads are exposed
when filter cover is removed.
Allow compressor to cool prior to
servicing.
A dirty air filter will not allow the
compressor to operate at full
capacity. Keep the air filter clean at
all times.
1.
Remove the air filter cover.
Air Filter
Cover
2.
Remove the air filter and make
sure it is clean.
IMPORTANT: Do not operate
the compressor with the air filter
removed.
3.
If dirty, rinse air filter with warm
water and squeeze dry.
4.
Replace air filter and air filter
cover.
NOTE: If the air filter is extremely
dirty it will need to be replaced. Refer
to the "Repair Parts" for the correct
part number.
Air Compressor Pump Intake
and Exhaust Valves
Once a year have a Trained Service
Technician check the air compressor
pump intake and exhaust valves.
Motor
The motor has an automatic reset
thermal overload protector. If the
motor overheats for any reason, the
overload protector will shut off the
motor. The motor must be allowed
to cool down before restarting. The
compressor will automatically restart
Air Filter
after the motor cools.
If the overload protector shuts the
motor off frequently, check for a
possible voltage problem. Low
voltage can also be suspected when:
1.
The motor does not get up to full
power or speed.
2.
Fuses blow out when starting
the motor; lights dim and remain
dim when motor is started and is
running.
17 - ENG
A14123

Publicité

loading