INSTALLATION
For reduced clearances installation must comply with
NFPA 211or CAN/CSA-B365.
For clearances when installed with blower kit EP63, refer
to page 6.
Alcove installation
Model 1600C-1 may be installed into an alcove having a
depth of not more than 4 feet and a height of at least 7 feet,
when using a listed double wall connector that is rated for a
minimum 12" clearance to combustible material.
The minimum clearances are as shown.
Alcove installation
1 6 "
2 2 "
1 6 "
4 f o o t m a x
Walls shall not extend from front of unit when installed
in the alcove configuration.
Stove installation
If the stove is to be installed on a
combustible floor, it must be
p l a c e d
o n
a
a p p r o v e d
non-combustible hearth pad,
t h a t e x t e n d s 8 " ( 2 0 0 m m )
beyond the stove sides and
back, and 18" (455mm) to the
front.
D
B
A
8 4 "
I l l u s t r a t e d w i t h . 7 5 " h e a r t h p a d .
8 "
8 "
8 "
1 8 "
C
E
C
Listed single wall chimney connector
Type 1
A
FROM
B*
UNIT
C
D
FROM
E
PIPE
* A 22 in. Minimum clearance must be maintained from
combustible wall to the chimney connector.
Double walled connectors listed for a minimum
clearance of 12" or less from combustible materials
must be used to achieve the following clearances.
Type 2
A
FROM
B
UNIT
C
D
FROM
E
PIPE
Flue configuration
Horizontal
Vertical
16"
16"
22"
22"
15"
15"
25"
25"
...
22"
Flue configuration
Horizontal
Vertical
16"
16"
14"
14"
15"
15"
25"
25"
...
16"
5