Connection Plugs
120 VAC, Duplex Receptacle
See
2-3. The 120 Volt outlet is overload
Figure
protected by the 15 Amp push button circuit
protector. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 1700 watts (1.7 kW).
Figure 2-3. 120 VAC, Duplex Receptacle
Off/Run/Choke Switch
See
2-4. This controls the ON/OFF
Figure
functions, choke and fuel valve operation.
• The OFF position (1) stops the engine and
shuts off fuel flow.
• The RUN position (2) is for normal opera-
tion and to gradually reduce the use of the
choke.
• The CHOKE position (3) switches the fuel
valve on to start the engine.
NOTE: The CHOKE is not required to start a
warm engine.
1
Figure 2-4. Dial (example)
USB Outlet
The 5 VDC, 1.5 Amp USB outlet allows
charging of compatible electronic devices.
6
Economy Switch
The economy switch has 2 modes of opera-
tion:
• On: The quietest mode and best when run-
ning appliances or equipment that are
resistive loads (non-motor starting), (exam-
ple: TV, video game, light, radio).
• Off: Best when running a both inductive
(motor-starting loads) and resistive (non-
motor starting loads), especially when
these loads are turning on and off (exam-
ple: RV, air conditioner, hairdryer).
Generator Status Lights
See
Figure
• Low Oil Level LED (red): Illuminates when
oil level is below safe operating level.
Engine shuts down (1).
• Overload LED (red): Indicates system
overload (2). During motor starting it is nor-
mal for the overload LED to illuminate for a
000424
few seconds. If LED stays illuminated and
the ready LED turns off, the engine will con-
tinue to run without output power. Remove
all applied loads and determine if attached
devices
power. Check for faulty or shorted connec-
tions. To restore electrical output, turn dial
OFF to reset. Start engine. If condition was
corrected, the red LED will not illuminate
and electrical output will be restored. Loads
can be applied once the green LED illumi-
nates. If the red LED returns, contact an
IASD.
• Power LED (green): Indicates output from
generator (3) (unless there is a low oil or
overload condition).
2
3
1
002347
Circuit Protectors
The AC receptacles are protected by an AC
circuit protector. The DC receptacles are pro-
tected by a DC circuit protector. If the genera-
tor is overloaded or an external short circuit
occurs, the circuit protector will trip. If this
occurs, disconnect all electrical loads to deter-
mine the cause of the problem before using
the generator again. Reduce the load if the cir-
cuit protector is tripped.
2-5.
exceed
recommended
2
Figure 2-5. Status Indicators
Owner's Manual for Portable Generator