5. See
Figure
3-2. When engine starts, rotate
Off/Run/Choke dial to RUN (2). Choke
operation is reduced as Off/Run/Choke
dial is rotated towards RUN.
NOTE: If engine fires, but does not continue to
run, rotate the Off/Run/Choke dial to OFF and
repeat starting instructions.
IMPORTANT NOTE: See
overload generator or individual panel
receptacles. If an overload occurs, the
overload LED (A) will illuminate and AC
output ceases. To correct, see
Status
Lights. Read
carefully.
.
B
Figure 3-3.Shutdown Fault
Generator Shut Down
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. Shut off all loads and unplug electrical
loads from generator panel receptacles.
2. Let engine run at no-load for several min-
utes to stabilize internal temperatures of
engine and generator.
3. See
3-2. Rotate Off/Run/Choke dial
Figure
to OFF (3).
4. Turn fuel cap OFF.
Restarting Hot Engines
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. See
Figure
3-2. Turn Off/Run/Choke dial
from STOP to RUN. This will open the fuel
valve and permit starting.
2. Firmly grasp recoil handle and pull slowly
until increased resistance is felt. Pull rap-
idly up and away.
Owner's Manual for Portable Generator
3-3. Do not
Figure
Generator
Know Generator Limits
A
CAUTION
CAUTION
Low Oil Level Shutdown System
The engine is equipped with a low oil level
sensor to shut down the engine automatically
when the oil level drops below a specified
level. The engine will not run until the oil has
been filled to the proper level.
IMPORTANT NOTE: Verify proper engine oil
and fuel levels before use.
Charging a 12 VDC Battery
NOTE: A battery may lose some of its charge
002335
when not in use for prolonged periods of time.
The DC charging output is not regulated. The
circuit protector does not prevent over
charging a battery. Battery charging should be
done in a dry location.
1. Start generator and turn Economy switch
OFF.
2. See
Cable into Battery Charger Output jack,
located on the control panel.
(000136)
3. Connect positive (+) battery clamp (red
wire) to battery FIRST.
4. Connect negative (-) battery clamp (black
wire) to battery SECOND.
NOTE: This receptacle can not recharge 6-
volt batteries and can not be used to crank an
engine having a discharged battery.
(000136)
Figure 3-4. Battery Charger Input Jack
Environmental Hazard. Always recycle batteries at an
official recycling center in accordance with all local
laws and regulations. Failure to do so could result in
environmental damage, death, or serious injury.
WARNING
Explosion. Batteries emit explosive gases while
charging. Keep fire and spark away. Wear protective
gear when working with batteries. Failure to do so
could result in death or serious injury.
WARNING
Risk of burns. Batteries contain sulfuric acid and can
cause severe chemical burns. Wear protective gear
when working with batteries. Failure to do so could
result in death or serious injury.
3-4. Plug Battery Charging
Figure
WARNING
(000137a)
(000138a)
004469
(000228)
11