Care and Cleaning (cont.)
Clogged Needle
1. Unplug and allow to cool.
2. Remove the gray removable needle
holder in the lid by turning the
arrow from the locked icon ( ) to the
unlocked icon ( ).
3. Bend a small paper clip. Insert the tip
of the paper clip through the hole of
the piercing needle and up into the
shaft of the piercing needle to ensure
grounds have been removed.
4. To replace the gray removable needle
holder, insert the tab between the lock
icon ( ) and unlock icon ( ) and turn to the right to lock.
Troubleshooting
Coffee maker will not brew/coffee not dispensing.
The piercing needle may be clogged. Always remove the gray
removable needle holder. Clean piercing needle in the lid of the
coffee maker as shown above.
Mineral deposits have formed. Clean coffee maker following the
directions in the Care and Cleaning section.
Too little water. Need 6 oz. (177 ml) or more.
Stopping the coffee maker before brewing is complete may cause
a clogged needle.
Water on counter under unit.
Overfilled water reservoir. Do not add more than 14 ounces
(414 ml) of water. Some mugs/cups do not pour cleanly and can
dribble water down the side of the cup and onto the counter.
Coffee overflows from funnel and single-serve pack holder.
Black seal around the needle in the removable needle holder is
missing. Carefully place seal around needle and push into place.