Anl WH 2000 PTC SPK1
12.05.2005
Mark the drill hole (4), drill the hole, insert the
dowel and fasten the holder to the wall with the
provided screw.
Note: The mains cable must be laid upwards through
the provided notch.
4. Technical data:
Rated voltage:
230 V ~ 50 Hz
Output:
2000 W (1000 W / 2000 W)
Timer:
1 to 7 hours
Protection type:
Mains lead:
3 x 1 mm2 x 1650 mm
5. Proper use
The appliance is designed only for private use, not
for commercial heating purposes.
6. Starting up
Important! Before using the appliance for the first
time, check that the voltage supply is the same as
the voltage details set out on the data plate.
Read the safety instructions listed in section 1.
6.1 Function switch (Fig. 3):
All modes and functions can be set using the
pushbuttons on the appliance as well as with the
remote control. The remote control runs on 2
batteries type "AAA". Make sure that the poles are
not reversed when you change the batteries. Used
batteries must be disposed off properly.
6.1.1 Cool blow mode
Press the "ON/OFF" button (1), the device turns
itself on and runs in the cool blow mode (no
heating output); LED 5 comes on. Press the button
(1) again and the device shuts down.
6.1.2 Heating mode
1000 watts: Press the "ON/OFF" button (1), then
the "Heater" button (3) - the device runs on the
lowest heat setting, LEDs 5 and 6 come on; press
the "ON/OFF" button (1) to turn off the device
again. If there is still residual heat, the fan will
continue to run and LED 5 will flash. The appliance
shuts down as soon as the residual heat has been
14:58 Uhr
Seite 7
dissipated.
2000 watts: Press the "ON/OFF" button (1), then
press the "Heater" button (3) twice – the device
runs on the highest heat setting, LEDs 5, 6 and 8
come on; press the "Heater" button again and the
device changes to cool blow mode; press the
"ON/OFF" button (1) and the device shuts down. If
there is still residual heat, the fan will continue to
run and LED 5 will flash. The appliance shuts
down as soon as the residual heat has been
dissipated.
6.1.3 Timer function (Time)
Set the cool blow mode or heating mode as
IPX0
describe above, press the "Timer" button (4) once;
the appliance runs with the timer function and
shuts down automatically after 1 hour. The timer
can be set for a period from 1 to 7 hours by
repeatedly pressing the "Timer" button (4). The 1
to 4 hours LEDs light up in different combinations
depending on the selected timer period (for
example if 3 hours are selected, LEDs 1h + 2h will
light up). To turn off the timer function press the
"Timer" button (4) once more after selecting the 7
hours period, or turn off the device completely with
the "ON/OFF" button (1).
Important! After turning off the appliance the fan will
continue to run until the heater has completely cooled
down.
6.1.4 The "Swing" function of the air outlet slats
Set the cool blow mode or heating mode as
described above. Press the "Swing" button (3). The
"Swing function" of the air outlet slats is activated,
enabling the slats to be swung up and down
electrically.
To switch off the "Swing" function and have the
appliance blow in one specific direction, press the
"Swing" button (4) again.
If the "Swing" function is selected together with the
cool blow mode the appliance will not continue to
run after the "ON/OFF" button is pressed.
7. Overheating guard
In case of excessive heating, the heating function
shuts down automatically. If this occurs, turn off the
appliance, disconnect the mains plug and wait a few
minutes for the appliance to cool. After eliminating
the cause (e.g. a covered air grille), the appliance
can be switched on again. If the overheating guard
triggers repeatedly, please contact your customer
service center (in Germany ISC GmbH).